Yan Ye, Taijun Liu, Xingbin Zeng, Jiaming He, C. Akyel
{"title":"用腔微扰技术精确测量ISM 5.8GHz频段介电常数","authors":"Yan Ye, Taijun Liu, Xingbin Zeng, Jiaming He, C. Akyel","doi":"10.1109/ICMMT.2007.381367","DOIUrl":null,"url":null,"abstract":"In this paper, a new calibration method with two-filling factors for the permittivity measurement is proposed. With this calibration method, it is not necessary to measure the volume of the small sample, which not only eliminates the measurement error of the sample volume, but also simplifies the measurement procedure. To improve the measurement accuracy, the Cursor method, the resonance curve area (RCA) method and the Lorentzian fit method are utilized to process the measured resonant curve data so as to obtain accurate resonant frequency and quality factor. Finally, the obtained permittivity measurement results of a liquid sample validate the accuracy of this permittivity measurement approach.","PeriodicalId":409971,"journal":{"name":"2007 International Conference on Microwave and Millimeter Wave Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Accurate Permittivity Measurement Using the Cavity Perturbation Technique at ISM 5.8GHz Radio Band\",\"authors\":\"Yan Ye, Taijun Liu, Xingbin Zeng, Jiaming He, C. Akyel\",\"doi\":\"10.1109/ICMMT.2007.381367\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new calibration method with two-filling factors for the permittivity measurement is proposed. With this calibration method, it is not necessary to measure the volume of the small sample, which not only eliminates the measurement error of the sample volume, but also simplifies the measurement procedure. To improve the measurement accuracy, the Cursor method, the resonance curve area (RCA) method and the Lorentzian fit method are utilized to process the measured resonant curve data so as to obtain accurate resonant frequency and quality factor. Finally, the obtained permittivity measurement results of a liquid sample validate the accuracy of this permittivity measurement approach.\",\"PeriodicalId\":409971,\"journal\":{\"name\":\"2007 International Conference on Microwave and Millimeter Wave Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 International Conference on Microwave and Millimeter Wave Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMMT.2007.381367\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Conference on Microwave and Millimeter Wave Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMMT.2007.381367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Accurate Permittivity Measurement Using the Cavity Perturbation Technique at ISM 5.8GHz Radio Band
In this paper, a new calibration method with two-filling factors for the permittivity measurement is proposed. With this calibration method, it is not necessary to measure the volume of the small sample, which not only eliminates the measurement error of the sample volume, but also simplifies the measurement procedure. To improve the measurement accuracy, the Cursor method, the resonance curve area (RCA) method and the Lorentzian fit method are utilized to process the measured resonant curve data so as to obtain accurate resonant frequency and quality factor. Finally, the obtained permittivity measurement results of a liquid sample validate the accuracy of this permittivity measurement approach.