有源电压质量调节器的可变直流母线控制策略

G. Xiao, Zhiliang Hu, Lei Zhang, Zhaoan Wang
{"title":"有源电压质量调节器的可变直流母线控制策略","authors":"G. Xiao, Zhiliang Hu, Lei Zhang, Zhaoan Wang","doi":"10.1109/APEC.2009.4802875","DOIUrl":null,"url":null,"abstract":"In order to avoid conventional topology's drawbacks, a new topology that the diode rectifier is replaced by the thyristor rectifier and the control strategy of the active voltage quality regulator with variable dc-bus voltage are proposed in this paper. This paper analyzes the circuit topology and control strategy in detail. Then losses and efficiency of the both circuit topologies are compared in order to show the virtue of the proposed circuit and its control method. Through comparative analysis, the proposed circuit topology is verified to be better than conventional topology. At last, the validity and effectiveness of the proposed control strategy are verified by the laboratory experimental results. At the same source voltage and load condition, the efficiency increases from 89% to 96% on a 2 kVA prototype.","PeriodicalId":200366,"journal":{"name":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","volume":"231 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Variable Dc-bus Control Strategy for an Active Voltage Quality Regulator\",\"authors\":\"G. Xiao, Zhiliang Hu, Lei Zhang, Zhaoan Wang\",\"doi\":\"10.1109/APEC.2009.4802875\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to avoid conventional topology's drawbacks, a new topology that the diode rectifier is replaced by the thyristor rectifier and the control strategy of the active voltage quality regulator with variable dc-bus voltage are proposed in this paper. This paper analyzes the circuit topology and control strategy in detail. Then losses and efficiency of the both circuit topologies are compared in order to show the virtue of the proposed circuit and its control method. Through comparative analysis, the proposed circuit topology is verified to be better than conventional topology. At last, the validity and effectiveness of the proposed control strategy are verified by the laboratory experimental results. At the same source voltage and load condition, the efficiency increases from 89% to 96% on a 2 kVA prototype.\",\"PeriodicalId\":200366,\"journal\":{\"name\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"volume\":\"231 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2009.4802875\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2009.4802875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

为了避免传统拓扑结构的缺陷,本文提出了用晶闸管整流器代替二极管整流器的新拓扑结构和直流母线电压可变有源电压质量调节器的控制策略。本文详细分析了电路拓扑结构和控制策略。然后比较了两种电路拓扑的损耗和效率,以显示所提出的电路及其控制方法的优点。通过对比分析,验证了该电路拓扑优于传统拓扑。最后,通过实验室实验结果验证了所提控制策略的有效性。在相同的源电压和负载条件下,在2 kVA样机上,效率从89%提高到96%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Variable Dc-bus Control Strategy for an Active Voltage Quality Regulator
In order to avoid conventional topology's drawbacks, a new topology that the diode rectifier is replaced by the thyristor rectifier and the control strategy of the active voltage quality regulator with variable dc-bus voltage are proposed in this paper. This paper analyzes the circuit topology and control strategy in detail. Then losses and efficiency of the both circuit topologies are compared in order to show the virtue of the proposed circuit and its control method. Through comparative analysis, the proposed circuit topology is verified to be better than conventional topology. At last, the validity and effectiveness of the proposed control strategy are verified by the laboratory experimental results. At the same source voltage and load condition, the efficiency increases from 89% to 96% on a 2 kVA prototype.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信