用于医疗监测应用的多层和双频CB-CPW Fed可穿戴天线

K. Sajith, J. Gandhimohan, T. Shanmuganantham
{"title":"用于医疗监测应用的多层和双频CB-CPW Fed可穿戴天线","authors":"K. Sajith, J. Gandhimohan, T. Shanmuganantham","doi":"10.1109/ICCTCT.2018.8551162","DOIUrl":null,"url":null,"abstract":"In this paper introduced the recent SRR loaded proposed conductor backed coplanar wave guide fed wearable antenna is exceptionally essential part for wearable transceiver module for healthcare monitoring. This antenna designed to fine-tune at resonating frequency 2.4GHz and 3.5GHz.this is the one of the on-body narrow band communication ISM and Wi-MAX frequency band. This is SRR loaded antenna; hence it has high gain, bandwidth, and flexible frequency tuning. The simulated results for the magnitude of reflection coefficient are −32dB at 2.4GHz, −25dB at 3.4GHz for non-SRR loaded structure, −16dB at 2.37GHz and −24dB at 3.57GHz for SRR loaded antenna respectively. The antenna required characteristic like such as far-field configuration, magnitude of reflection coefficient, VSWR and gain of the proposed antenna is presented.","PeriodicalId":344188,"journal":{"name":"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Multilayered and Dual-Band CB-CPW Fed Wearable Antenna for Healthcare Monitoring Applications\",\"authors\":\"K. Sajith, J. Gandhimohan, T. Shanmuganantham\",\"doi\":\"10.1109/ICCTCT.2018.8551162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper introduced the recent SRR loaded proposed conductor backed coplanar wave guide fed wearable antenna is exceptionally essential part for wearable transceiver module for healthcare monitoring. This antenna designed to fine-tune at resonating frequency 2.4GHz and 3.5GHz.this is the one of the on-body narrow band communication ISM and Wi-MAX frequency band. This is SRR loaded antenna; hence it has high gain, bandwidth, and flexible frequency tuning. The simulated results for the magnitude of reflection coefficient are −32dB at 2.4GHz, −25dB at 3.4GHz for non-SRR loaded structure, −16dB at 2.37GHz and −24dB at 3.57GHz for SRR loaded antenna respectively. The antenna required characteristic like such as far-field configuration, magnitude of reflection coefficient, VSWR and gain of the proposed antenna is presented.\",\"PeriodicalId\":344188,\"journal\":{\"name\":\"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCTCT.2018.8551162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCTCT.2018.8551162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了一种新型的SRR负载共面波导馈电可穿戴天线,它是医疗监测用可穿戴收发模块的重要组成部分。该天线设计用于在2.4GHz和3.5GHz谐振频率下进行微调。这是其中一个体上窄带通信ISM和Wi-MAX频段。这是SRR负载天线;因此,它具有高增益,带宽和灵活的频率调谐。非SRR负载天线在2.4GHz时的反射系数幅值为- 32dB, 3.4GHz时的反射系数幅值为- 25dB, SRR负载天线在2.37GHz时的反射系数幅值为- 16dB, 3.57GHz时反射系数幅值为- 24dB。给出了天线所需的远场结构、反射系数大小、驻波比和增益等特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multilayered and Dual-Band CB-CPW Fed Wearable Antenna for Healthcare Monitoring Applications
In this paper introduced the recent SRR loaded proposed conductor backed coplanar wave guide fed wearable antenna is exceptionally essential part for wearable transceiver module for healthcare monitoring. This antenna designed to fine-tune at resonating frequency 2.4GHz and 3.5GHz.this is the one of the on-body narrow band communication ISM and Wi-MAX frequency band. This is SRR loaded antenna; hence it has high gain, bandwidth, and flexible frequency tuning. The simulated results for the magnitude of reflection coefficient are −32dB at 2.4GHz, −25dB at 3.4GHz for non-SRR loaded structure, −16dB at 2.37GHz and −24dB at 3.57GHz for SRR loaded antenna respectively. The antenna required characteristic like such as far-field configuration, magnitude of reflection coefficient, VSWR and gain of the proposed antenna is presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信