在微流控芯片上集成检测器直接检测DNA

W. Kuhr, C. B. Davis, S. Brazill
{"title":"在微流控芯片上集成检测器直接检测DNA","authors":"W. Kuhr, C. B. Davis, S. Brazill","doi":"10.1109/IMNC.1999.797477","DOIUrl":null,"url":null,"abstract":"A microfluidic chip has been developed which allows for the direct detection of several distinct DNA targets present in a sample. The direct detection of underivatized DNA is advantageous for the analysis of very small amounts of sample, where contamination is a major concern. DNA probes can be attached in microchannels present on the chip via a biotin/avidin linkage. The sample is then introduced into the channel where an appropriate DNA target hybridizes with its complementary probe. Following hybridization of the target, an alkaline buffer is introduced to the channel to dehybridize the double-stranded DNA and flush the target downstream to a copper electrode. The dehybridized DNA is then detected electrochemically. The elution time can be used to identify the particular DNA target since the DNA probes are spatially segregated in the channel. Integrating the detector and the sensing probes on the microfluidic chip allows for an inexpensive and easily fabricated biosensor device for the precise recognition and subsequent detection of a specific complimentary DNA target for diagnosis and genetic screening.","PeriodicalId":120440,"journal":{"name":"Digest of Papers. Microprocesses and Nanotechnology '99. 1999 International Microprocesses and Nanotechnology Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Direct detection of DNA with an integrated detector on a microfluidic chip\",\"authors\":\"W. Kuhr, C. B. Davis, S. Brazill\",\"doi\":\"10.1109/IMNC.1999.797477\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A microfluidic chip has been developed which allows for the direct detection of several distinct DNA targets present in a sample. The direct detection of underivatized DNA is advantageous for the analysis of very small amounts of sample, where contamination is a major concern. DNA probes can be attached in microchannels present on the chip via a biotin/avidin linkage. The sample is then introduced into the channel where an appropriate DNA target hybridizes with its complementary probe. Following hybridization of the target, an alkaline buffer is introduced to the channel to dehybridize the double-stranded DNA and flush the target downstream to a copper electrode. The dehybridized DNA is then detected electrochemically. The elution time can be used to identify the particular DNA target since the DNA probes are spatially segregated in the channel. Integrating the detector and the sensing probes on the microfluidic chip allows for an inexpensive and easily fabricated biosensor device for the precise recognition and subsequent detection of a specific complimentary DNA target for diagnosis and genetic screening.\",\"PeriodicalId\":120440,\"journal\":{\"name\":\"Digest of Papers. Microprocesses and Nanotechnology '99. 1999 International Microprocesses and Nanotechnology Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Papers. Microprocesses and Nanotechnology '99. 1999 International Microprocesses and Nanotechnology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMNC.1999.797477\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Papers. Microprocesses and Nanotechnology '99. 1999 International Microprocesses and Nanotechnology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMNC.1999.797477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一种微流控芯片已经开发出来,它可以直接检测样品中存在的几种不同的DNA目标。直接检测未分化的DNA有利于分析非常少量的样品,其中污染是一个主要问题。DNA探针可以通过生物素/亲和素连接连接到芯片上的微通道中。然后将样品引入通道中,其中适当的DNA靶与其互补探针杂交。在目标的杂交之后,将碱性缓冲液引入通道以使双链DNA去杂交并将目标冲洗到下游的铜电极上。然后用电化学方法检测去杂交的DNA。由于DNA探针在通道中是空间分离的,因此可以利用洗脱时间来识别特定的DNA目标。在微流控芯片上集成检测器和传感探针允许廉价和易于制造的生物传感器设备,用于精确识别和随后检测用于诊断和遗传筛查的特定互补DNA靶标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Direct detection of DNA with an integrated detector on a microfluidic chip
A microfluidic chip has been developed which allows for the direct detection of several distinct DNA targets present in a sample. The direct detection of underivatized DNA is advantageous for the analysis of very small amounts of sample, where contamination is a major concern. DNA probes can be attached in microchannels present on the chip via a biotin/avidin linkage. The sample is then introduced into the channel where an appropriate DNA target hybridizes with its complementary probe. Following hybridization of the target, an alkaline buffer is introduced to the channel to dehybridize the double-stranded DNA and flush the target downstream to a copper electrode. The dehybridized DNA is then detected electrochemically. The elution time can be used to identify the particular DNA target since the DNA probes are spatially segregated in the channel. Integrating the detector and the sensing probes on the microfluidic chip allows for an inexpensive and easily fabricated biosensor device for the precise recognition and subsequent detection of a specific complimentary DNA target for diagnosis and genetic screening.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信