E Music, M Flezar, S Suskovic
{"title":"[沙丁胺醇直接雾化或间隔剂对支气管扩张的影响]。","authors":"E Music,&nbsp;M Flezar,&nbsp;S Suskovic","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>During three successive days in 14 patients with bronchial asthma after application of Salbutamol directly from the metered-dose inhaler (MDI) or indirectly by spacer the changes of FEF and FEV1 were measured. For inhalation through spacer the double blind crossover trial with placebo was used. Out of 12 patients three of them responded with better flows (FEV1, FEF) after inhalation via MDI. In 7 of them there were no significant differences between ways of application while in two of them the flows by spacer were significantly better. Tachypnea, low lung volumes as well as poor co-operation of the patient, especially elderly, should speak in favour of the use of spacer. However, in young, co-operative asthmatic patients the MDI is suitable. Further controlled studies of new applications of inhalation therapy should be studied.</p>","PeriodicalId":77589,"journal":{"name":"Plucne bolesti : casopis Udruzenja pneumoftiziologa Jugoslavije = the journal of Yugoslav Association of Phthisiology and Pneumology","volume":"42 3-4","pages":"199-202"},"PeriodicalIF":0.0000,"publicationDate":"1990-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Effect of salbutamol administered directly by a nebulizer or by means of a spacer on bronchodilation].\",\"authors\":\"E Music,&nbsp;M Flezar,&nbsp;S Suskovic\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>During three successive days in 14 patients with bronchial asthma after application of Salbutamol directly from the metered-dose inhaler (MDI) or indirectly by spacer the changes of FEF and FEV1 were measured. For inhalation through spacer the double blind crossover trial with placebo was used. Out of 12 patients three of them responded with better flows (FEV1, FEF) after inhalation via MDI. In 7 of them there were no significant differences between ways of application while in two of them the flows by spacer were significantly better. Tachypnea, low lung volumes as well as poor co-operation of the patient, especially elderly, should speak in favour of the use of spacer. However, in young, co-operative asthmatic patients the MDI is suitable. Further controlled studies of new applications of inhalation therapy should be studied.</p>\",\"PeriodicalId\":77589,\"journal\":{\"name\":\"Plucne bolesti : casopis Udruzenja pneumoftiziologa Jugoslavije = the journal of Yugoslav Association of Phthisiology and Pneumology\",\"volume\":\"42 3-4\",\"pages\":\"199-202\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plucne bolesti : casopis Udruzenja pneumoftiziologa Jugoslavije = the journal of Yugoslav Association of Phthisiology and Pneumology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plucne bolesti : casopis Udruzenja pneumoftiziologa Jugoslavije = the journal of Yugoslav Association of Phthisiology and Pneumology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对14例支气管哮喘患者经直接或间接吸入沙丁胺醇后,连续3 d测定FEF和FEV1的变化。通过间隔剂吸入采用双盲交叉试验与安慰剂。12例患者中有3例经MDI吸入后血流(FEV1, FEF)较好。其中7种应用方式间无显著性差异,其中2种应用间隔器的流量明显更好。呼吸急促,肺容量低以及患者配合不良,特别是老年人,应该支持使用间隔器。然而,对于年轻的哮喘患者,MDI是合适的。吸入疗法的新应用需要进一步的对照研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Effect of salbutamol administered directly by a nebulizer or by means of a spacer on bronchodilation].

During three successive days in 14 patients with bronchial asthma after application of Salbutamol directly from the metered-dose inhaler (MDI) or indirectly by spacer the changes of FEF and FEV1 were measured. For inhalation through spacer the double blind crossover trial with placebo was used. Out of 12 patients three of them responded with better flows (FEV1, FEF) after inhalation via MDI. In 7 of them there were no significant differences between ways of application while in two of them the flows by spacer were significantly better. Tachypnea, low lung volumes as well as poor co-operation of the patient, especially elderly, should speak in favour of the use of spacer. However, in young, co-operative asthmatic patients the MDI is suitable. Further controlled studies of new applications of inhalation therapy should be studied.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信