Ievgen Pichkalov, A. Kyselova, O. Kyselova, G. Kyselov
{"title":"柴油发电机不间断电力系统的最优控制","authors":"Ievgen Pichkalov, A. Kyselova, O. Kyselova, G. Kyselov","doi":"10.1109/ELNANO.2013.6552001","DOIUrl":null,"url":null,"abstract":"Conditions to minimize fuel consumption in uninterruptible power system with diesel generator at variable load are obtained. Estimation of fuel consumption at acceleration and braking stages of diesel generator was executed taking into account the cost of battery charge. Minimization of fuel consumption required for the transition process is achieved by adjusting the position of the fuel valves. Minimization of fuel consumption is shown for diesel generator HATZ 1D90-Supra.","PeriodicalId":443634,"journal":{"name":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Optimal control of uninterruptible power system with diesel generator\",\"authors\":\"Ievgen Pichkalov, A. Kyselova, O. Kyselova, G. Kyselov\",\"doi\":\"10.1109/ELNANO.2013.6552001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conditions to minimize fuel consumption in uninterruptible power system with diesel generator at variable load are obtained. Estimation of fuel consumption at acceleration and braking stages of diesel generator was executed taking into account the cost of battery charge. Minimization of fuel consumption required for the transition process is achieved by adjusting the position of the fuel valves. Minimization of fuel consumption is shown for diesel generator HATZ 1D90-Supra.\",\"PeriodicalId\":443634,\"journal\":{\"name\":\"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELNANO.2013.6552001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELNANO.2013.6552001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimal control of uninterruptible power system with diesel generator
Conditions to minimize fuel consumption in uninterruptible power system with diesel generator at variable load are obtained. Estimation of fuel consumption at acceleration and braking stages of diesel generator was executed taking into account the cost of battery charge. Minimization of fuel consumption required for the transition process is achieved by adjusting the position of the fuel valves. Minimization of fuel consumption is shown for diesel generator HATZ 1D90-Supra.