{"title":"无线传感器网络时间同步的自回归集成模型","authors":"Wasif Masood, J. F. Schmidt","doi":"10.1145/2811587.2811591","DOIUrl":null,"url":null,"abstract":"Time synchronization is challenging in wireless sensor networks due to the use of low-precision oscillators and the limited computational capacity of resources limited sensor nodes. While several schemes exist, the performance analysis of a majority of them is based on simulations and fail to capture key features of real world deployments. This paper explores the use of autoregressive integrated moving average models to provide a general clock model for sensor nodes with low precision oscillators and limited computational power. Based on measurements with off-the-shelf sensor devices Z1, an autoregressive integrated model for time synchronization is proposed. We derive a synchronization scheme (ARI-Sync) based on this model and compare it against the well known Flooding Time Synchronization Protocol (FTSP) observing significantly improved accuracy, roughly doubling the resynchronization period of Z1 nodes for a typical wireless sensor network application.","PeriodicalId":371317,"journal":{"name":"Proceedings of the 18th ACM International Conference on Modeling, Analysis and Simulation of Wireless and Mobile Systems","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Autoregressive Integrated Model for Time Synchronization in Wireless Sensor Networks\",\"authors\":\"Wasif Masood, J. F. Schmidt\",\"doi\":\"10.1145/2811587.2811591\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Time synchronization is challenging in wireless sensor networks due to the use of low-precision oscillators and the limited computational capacity of resources limited sensor nodes. While several schemes exist, the performance analysis of a majority of them is based on simulations and fail to capture key features of real world deployments. This paper explores the use of autoregressive integrated moving average models to provide a general clock model for sensor nodes with low precision oscillators and limited computational power. Based on measurements with off-the-shelf sensor devices Z1, an autoregressive integrated model for time synchronization is proposed. We derive a synchronization scheme (ARI-Sync) based on this model and compare it against the well known Flooding Time Synchronization Protocol (FTSP) observing significantly improved accuracy, roughly doubling the resynchronization period of Z1 nodes for a typical wireless sensor network application.\",\"PeriodicalId\":371317,\"journal\":{\"name\":\"Proceedings of the 18th ACM International Conference on Modeling, Analysis and Simulation of Wireless and Mobile Systems\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 18th ACM International Conference on Modeling, Analysis and Simulation of Wireless and Mobile Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2811587.2811591\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 18th ACM International Conference on Modeling, Analysis and Simulation of Wireless and Mobile Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2811587.2811591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Autoregressive Integrated Model for Time Synchronization in Wireless Sensor Networks
Time synchronization is challenging in wireless sensor networks due to the use of low-precision oscillators and the limited computational capacity of resources limited sensor nodes. While several schemes exist, the performance analysis of a majority of them is based on simulations and fail to capture key features of real world deployments. This paper explores the use of autoregressive integrated moving average models to provide a general clock model for sensor nodes with low precision oscillators and limited computational power. Based on measurements with off-the-shelf sensor devices Z1, an autoregressive integrated model for time synchronization is proposed. We derive a synchronization scheme (ARI-Sync) based on this model and compare it against the well known Flooding Time Synchronization Protocol (FTSP) observing significantly improved accuracy, roughly doubling the resynchronization period of Z1 nodes for a typical wireless sensor network application.