J. Paulino, Wallace Do C. Boaventura, Ivan Jose Da S. Lopes, Celio Fonseca Barbosa
{"title":"用均匀接地模型计算雷击电压","authors":"J. Paulino, Wallace Do C. Boaventura, Ivan Jose Da S. Lopes, Celio Fonseca Barbosa","doi":"10.1109/SIPDA.2015.7339308","DOIUrl":null,"url":null,"abstract":"Lightning induced voltages on aerial and underground lines depend on the ground resistivity. Most calculating methodologies were developed considering the ground as a homogeneous medium. However, actual ground is better represented if stratified into horizontal layers of different resistivity values. This paper proposes the use of a simplified expression for the calculation of the equivalent resistivity of a uniform ground that can represent a two-layer stratified ground in lightning induced voltage calculations. The analysis is made by comparing the results from a homogeneous ground having the equivalent resistivity value with results from two-layer ground. It is shown that, for the range of parameters considered, the absolute average and maximum errors on the induced voltage peak values are 2.9% and 8.2%, respectively. It is also shown that, with the equivalent resistivity, a peak-value formula developed for uniform ground could be used for the calculation of lightning induced voltages on lines above two-layer ground.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"On the use of homogeneous ground model for lightning-induced voltage calculation\",\"authors\":\"J. Paulino, Wallace Do C. Boaventura, Ivan Jose Da S. Lopes, Celio Fonseca Barbosa\",\"doi\":\"10.1109/SIPDA.2015.7339308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning induced voltages on aerial and underground lines depend on the ground resistivity. Most calculating methodologies were developed considering the ground as a homogeneous medium. However, actual ground is better represented if stratified into horizontal layers of different resistivity values. This paper proposes the use of a simplified expression for the calculation of the equivalent resistivity of a uniform ground that can represent a two-layer stratified ground in lightning induced voltage calculations. The analysis is made by comparing the results from a homogeneous ground having the equivalent resistivity value with results from two-layer ground. It is shown that, for the range of parameters considered, the absolute average and maximum errors on the induced voltage peak values are 2.9% and 8.2%, respectively. It is also shown that, with the equivalent resistivity, a peak-value formula developed for uniform ground could be used for the calculation of lightning induced voltages on lines above two-layer ground.\",\"PeriodicalId\":296478,\"journal\":{\"name\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2015.7339308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

架空和地下线路上的雷击感应电压取决于地面电阻率。大多数计算方法都是将地面视为均匀介质而发展起来的。然而,如果将实际地面分层成不同电阻率值的水平层,则可以更好地表示实际地面。本文提出了在雷击电压计算中,用一种简化的表达式来计算能代表两层分层地的均匀地的等效电阻率。通过将具有等效电阻率值的均匀地层的结果与双层地层的结果进行对比分析。结果表明,在所考虑的参数范围内,感应电压峰值的绝对平均值和最大误差分别为2.9%和8.2%。利用等效电阻率,建立了均匀接地的峰值公式,可用于计算两层以上接地线路的雷击电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the use of homogeneous ground model for lightning-induced voltage calculation
Lightning induced voltages on aerial and underground lines depend on the ground resistivity. Most calculating methodologies were developed considering the ground as a homogeneous medium. However, actual ground is better represented if stratified into horizontal layers of different resistivity values. This paper proposes the use of a simplified expression for the calculation of the equivalent resistivity of a uniform ground that can represent a two-layer stratified ground in lightning induced voltage calculations. The analysis is made by comparing the results from a homogeneous ground having the equivalent resistivity value with results from two-layer ground. It is shown that, for the range of parameters considered, the absolute average and maximum errors on the induced voltage peak values are 2.9% and 8.2%, respectively. It is also shown that, with the equivalent resistivity, a peak-value formula developed for uniform ground could be used for the calculation of lightning induced voltages on lines above two-layer ground.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信