PMSG风力发电系统无传感器控制三相PFC整流器

Yingtao Ma, Xudong Sun, Jianyun Chai
{"title":"PMSG风力发电系统无传感器控制三相PFC整流器","authors":"Yingtao Ma, Xudong Sun, Jianyun Chai","doi":"10.1109/ICEMS.2011.6073895","DOIUrl":null,"url":null,"abstract":"A sensorless control strategy is proposed based on a novel topology for the rectification of the permanent magnetic synchronous generator (PMSG) in the wind generation system. Three one-phase power factor correction (PFC) circuits for each phase of PMSG, called three-phase PFC rectifier, are employed in this topology. Every stator current is controlled in phase with the corresponding electromotive force (EMF) of the PMSG. Based on the models of the PMSG and the PFC circuits, the EMF is reconstructed and the rotor flux linkage is observed. The phase angle for the current control is derived from the flux linkage using a phase locked loop (PLL). Results of both simulations and experiments verify that sinusoidal AC currents are in phase with the fundamental voltages of the EMFs of PMSG with the proposed sensorless control strategy.","PeriodicalId":101507,"journal":{"name":"2011 International Conference on Electrical Machines and Systems","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Three-phase PFC rectifier with sensorless control for PMSG wind generation system\",\"authors\":\"Yingtao Ma, Xudong Sun, Jianyun Chai\",\"doi\":\"10.1109/ICEMS.2011.6073895\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A sensorless control strategy is proposed based on a novel topology for the rectification of the permanent magnetic synchronous generator (PMSG) in the wind generation system. Three one-phase power factor correction (PFC) circuits for each phase of PMSG, called three-phase PFC rectifier, are employed in this topology. Every stator current is controlled in phase with the corresponding electromotive force (EMF) of the PMSG. Based on the models of the PMSG and the PFC circuits, the EMF is reconstructed and the rotor flux linkage is observed. The phase angle for the current control is derived from the flux linkage using a phase locked loop (PLL). Results of both simulations and experiments verify that sinusoidal AC currents are in phase with the fundamental voltages of the EMFs of PMSG with the proposed sensorless control strategy.\",\"PeriodicalId\":101507,\"journal\":{\"name\":\"2011 International Conference on Electrical Machines and Systems\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Electrical Machines and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMS.2011.6073895\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Electrical Machines and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMS.2011.6073895","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

针对风力发电系统中永磁同步发电机(PMSG)的整流问题,提出了一种基于新型拓扑结构的无传感器控制策略。在这种拓扑结构中,对PMSG的每一相采用三个单相功率因数校正(PFC)电路,称为三相PFC整流器。每个定子电流都与PMSG的相应电动势(EMF)相控制。在PMSG和PFC电路模型的基础上,重构了电动势,观察了转子磁链。采用锁相环(PLL)从磁链中导出电流控制的相位角。仿真和实验结果验证了所提出的无传感器控制策略下PMSG的交流正弦电流与emf的基态电压是一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-phase PFC rectifier with sensorless control for PMSG wind generation system
A sensorless control strategy is proposed based on a novel topology for the rectification of the permanent magnetic synchronous generator (PMSG) in the wind generation system. Three one-phase power factor correction (PFC) circuits for each phase of PMSG, called three-phase PFC rectifier, are employed in this topology. Every stator current is controlled in phase with the corresponding electromotive force (EMF) of the PMSG. Based on the models of the PMSG and the PFC circuits, the EMF is reconstructed and the rotor flux linkage is observed. The phase angle for the current control is derived from the flux linkage using a phase locked loop (PLL). Results of both simulations and experiments verify that sinusoidal AC currents are in phase with the fundamental voltages of the EMFs of PMSG with the proposed sensorless control strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信