Ardalan Lotfi, D. Demarchi, F. Puppo, G. Micheli, S. Carrara, M. Doucey
{"title":"具有记忆生物传感器的可靠冗余,在免疫传感中实现统计显著性","authors":"Ardalan Lotfi, D. Demarchi, F. Puppo, G. Micheli, S. Carrara, M. Doucey","doi":"10.1109/IWASI.2015.7184969","DOIUrl":null,"url":null,"abstract":"In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.","PeriodicalId":395550,"journal":{"name":"2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliable redundancy with memristive-biosensors to achieve statistical significance in immunosensing\",\"authors\":\"Ardalan Lotfi, D. Demarchi, F. Puppo, G. Micheli, S. Carrara, M. Doucey\",\"doi\":\"10.1109/IWASI.2015.7184969\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.\",\"PeriodicalId\":395550,\"journal\":{\"name\":\"2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWASI.2015.7184969\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWASI.2015.7184969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reliable redundancy with memristive-biosensors to achieve statistical significance in immunosensing
In this paper, we have investigated the redundancy in array of Memristive-Biosensors and find optimum number for devices to accomplish reliable biodetection. Our results lead less expensive sensor and reduce the low-reproducibility of this memristive method for the detection of rabbit antigen. Several experiments have been performed with 17 memristive biosensors in several conditions. These conditions give us relevant informations about the overall behavior of memristor biosensor's array, after functionalization with antibody and exposure to antigen. The statistics made on different conditions, related to the standard deviation and the mean value of voltage gap, prove that such a sensor, with a minimum memristive biosensors in array, can be counted as reliable sensor for the detection of antigen.