{"title":"太赫兹在晶圆上的校准使用偏移短路,并通过称为标准","authors":"C. Caglayan, G. Trichopoulos, K. Sertel","doi":"10.1109/NAECON.2014.7045823","DOIUrl":null,"url":null,"abstract":"We present a novel on-wafer calibration technique using well-defined standards that can be an alternative to widely used multiline-TRL (thru-reflect-line) calibration in millimeter and submillimeter waves. Our method is specifically useful in measurement setups with fixed probes since TRL-type calibration typically requires different physical separation between measurement probes. As on-wafer standards, offset shorts with different electrical delay lengths and a simple through connection are used. Experimental validation of this calibration method is provided in G-Band (140-220 GHz) via measurement of a Beatty standard (mismatched thru) using non-contact probes.","PeriodicalId":318539,"journal":{"name":"NAECON 2014 - IEEE National Aerospace and Electronics Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"THz on-wafer calibration using offset-shorts and known through as standards\",\"authors\":\"C. Caglayan, G. Trichopoulos, K. Sertel\",\"doi\":\"10.1109/NAECON.2014.7045823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a novel on-wafer calibration technique using well-defined standards that can be an alternative to widely used multiline-TRL (thru-reflect-line) calibration in millimeter and submillimeter waves. Our method is specifically useful in measurement setups with fixed probes since TRL-type calibration typically requires different physical separation between measurement probes. As on-wafer standards, offset shorts with different electrical delay lengths and a simple through connection are used. Experimental validation of this calibration method is provided in G-Band (140-220 GHz) via measurement of a Beatty standard (mismatched thru) using non-contact probes.\",\"PeriodicalId\":318539,\"journal\":{\"name\":\"NAECON 2014 - IEEE National Aerospace and Electronics Conference\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NAECON 2014 - IEEE National Aerospace and Electronics Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAECON.2014.7045823\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NAECON 2014 - IEEE National Aerospace and Electronics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAECON.2014.7045823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
THz on-wafer calibration using offset-shorts and known through as standards
We present a novel on-wafer calibration technique using well-defined standards that can be an alternative to widely used multiline-TRL (thru-reflect-line) calibration in millimeter and submillimeter waves. Our method is specifically useful in measurement setups with fixed probes since TRL-type calibration typically requires different physical separation between measurement probes. As on-wafer standards, offset shorts with different electrical delay lengths and a simple through connection are used. Experimental validation of this calibration method is provided in G-Band (140-220 GHz) via measurement of a Beatty standard (mismatched thru) using non-contact probes.