{"title":"陡锋浪涌下电机绕组电压分布的研究","authors":"H. Ishikawa, Y. Haga","doi":"10.1109/ISEIM.1995.496508","DOIUrl":null,"url":null,"abstract":"For inverter driven motors, it is important to investigate the coil voltage distribution for interturn insulation design. In this paper we researched form-wound coil voltages against steep-fronted surge. We present the results of investigations of the equivalent circuit of the windings, measurement of coil voltages and voltages-to-ground, simulation of them by EMTP (Electromagnetic Transients Program) and formulation of a numerical expression for the circuit constants.","PeriodicalId":130178,"journal":{"name":"Proceedings of 1995 International Symposium on Electrical Insulating Materials","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A study of voltage distribution in motor windings against steep-fronted surge\",\"authors\":\"H. Ishikawa, Y. Haga\",\"doi\":\"10.1109/ISEIM.1995.496508\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For inverter driven motors, it is important to investigate the coil voltage distribution for interturn insulation design. In this paper we researched form-wound coil voltages against steep-fronted surge. We present the results of investigations of the equivalent circuit of the windings, measurement of coil voltages and voltages-to-ground, simulation of them by EMTP (Electromagnetic Transients Program) and formulation of a numerical expression for the circuit constants.\",\"PeriodicalId\":130178,\"journal\":{\"name\":\"Proceedings of 1995 International Symposium on Electrical Insulating Materials\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1995 International Symposium on Electrical Insulating Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEIM.1995.496508\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 International Symposium on Electrical Insulating Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEIM.1995.496508","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A study of voltage distribution in motor windings against steep-fronted surge
For inverter driven motors, it is important to investigate the coil voltage distribution for interturn insulation design. In this paper we researched form-wound coil voltages against steep-fronted surge. We present the results of investigations of the equivalent circuit of the windings, measurement of coil voltages and voltages-to-ground, simulation of them by EMTP (Electromagnetic Transients Program) and formulation of a numerical expression for the circuit constants.