{"title":"基于变步长ILSE的SPV系统电能质量改善控制算法","authors":"Priyank Shah, Ikhlaq Hussain, Bhim Singh","doi":"10.1109/ICIINFS.2016.8263035","DOIUrl":null,"url":null,"abstract":"This paper proposes the use of a variable step based improved least sum of exponentials (VS-ILSE) control algorithm for single stage three phase grid connected photovoltaic (PV) system. The VS-ILSE algorithm provides a fundamental weight of active and reactive power components of load currents which are used to generate reference grid currents. This control algorithm provides the power quality improvement of distribution network likes load balancing, power factor correction. The perturb and observe (P&O) MPPT (Maximum Power Point Tracking) algorithm is used to obtain reference DC link voltage of VSC and also used to extract maximum power from the SPV array during varying environmental conditions. The proposed system is simulated in MATLAB®/Simulink based environment of simpower system toolbox. The proposed algorithm is verified on a developed hardware and obtained responses are found satisfactory. The total harmonics distortions (THDs) of the grid currents and CCP (Common Coupling Point) voltages are found well according to an IEEE-519 and IEEE-929 standards.","PeriodicalId":234609,"journal":{"name":"2016 11th International Conference on Industrial and Information Systems (ICIIS)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Variable step ILSE based control algorithm for power quality improvement of SPV system\",\"authors\":\"Priyank Shah, Ikhlaq Hussain, Bhim Singh\",\"doi\":\"10.1109/ICIINFS.2016.8263035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes the use of a variable step based improved least sum of exponentials (VS-ILSE) control algorithm for single stage three phase grid connected photovoltaic (PV) system. The VS-ILSE algorithm provides a fundamental weight of active and reactive power components of load currents which are used to generate reference grid currents. This control algorithm provides the power quality improvement of distribution network likes load balancing, power factor correction. The perturb and observe (P&O) MPPT (Maximum Power Point Tracking) algorithm is used to obtain reference DC link voltage of VSC and also used to extract maximum power from the SPV array during varying environmental conditions. The proposed system is simulated in MATLAB®/Simulink based environment of simpower system toolbox. The proposed algorithm is verified on a developed hardware and obtained responses are found satisfactory. The total harmonics distortions (THDs) of the grid currents and CCP (Common Coupling Point) voltages are found well according to an IEEE-519 and IEEE-929 standards.\",\"PeriodicalId\":234609,\"journal\":{\"name\":\"2016 11th International Conference on Industrial and Information Systems (ICIIS)\",\"volume\":\"94 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 11th International Conference on Industrial and Information Systems (ICIIS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIINFS.2016.8263035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 11th International Conference on Industrial and Information Systems (ICIIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIINFS.2016.8263035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Variable step ILSE based control algorithm for power quality improvement of SPV system
This paper proposes the use of a variable step based improved least sum of exponentials (VS-ILSE) control algorithm for single stage three phase grid connected photovoltaic (PV) system. The VS-ILSE algorithm provides a fundamental weight of active and reactive power components of load currents which are used to generate reference grid currents. This control algorithm provides the power quality improvement of distribution network likes load balancing, power factor correction. The perturb and observe (P&O) MPPT (Maximum Power Point Tracking) algorithm is used to obtain reference DC link voltage of VSC and also used to extract maximum power from the SPV array during varying environmental conditions. The proposed system is simulated in MATLAB®/Simulink based environment of simpower system toolbox. The proposed algorithm is verified on a developed hardware and obtained responses are found satisfactory. The total harmonics distortions (THDs) of the grid currents and CCP (Common Coupling Point) voltages are found well according to an IEEE-519 and IEEE-929 standards.