{"title":"具有薄层结构的导电传感器,用于水分分析","authors":"K. Mitsubayashi, Y. Miyoshi, T. Takeuchi, I. Karube","doi":"10.1109/COMMAD.2002.1237231","DOIUrl":null,"url":null,"abstract":"An electric conductimetric sensor (thickness: 80 /spl mu/m) constructed in a sandwich configuration with a hydrophilic poly-tetrafluoroethylene membrane placed between two gold deposited layers was evaluated for use as a moisture sensor. The humidity level was measured by electrical conductivity of the device using the Multi-frequency LCR-meter at frequencies ranging from 100 Hz to 100 k Hz, the device was calibrated at 100 Hz against the moisture air over the range of 30-85 % RH, which includes normal humidity level in the atmosphere and physiologic air such as breath and sweating. The response sensitivity of the conductimetric device was extremely high (i.e. less than 1 sec. for conductivity shift between humid air of 80 % RH and dried air of -60 /spl deg/C dew point) even for recovery to dried air. The sensor performance was reproducible over multiple measurements, showing the highly reproducibility with a coefficient of variation of 1.77 % (n = 5).","PeriodicalId":129668,"journal":{"name":"2002 Conference on Optoelectronic and Microelectronic Materials and Devices. COMMAD 2002. Proceedings (Cat. No.02EX601)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electric conductimetric sensor with a thin-layer structure for moisture analysis\",\"authors\":\"K. Mitsubayashi, Y. Miyoshi, T. Takeuchi, I. Karube\",\"doi\":\"10.1109/COMMAD.2002.1237231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An electric conductimetric sensor (thickness: 80 /spl mu/m) constructed in a sandwich configuration with a hydrophilic poly-tetrafluoroethylene membrane placed between two gold deposited layers was evaluated for use as a moisture sensor. The humidity level was measured by electrical conductivity of the device using the Multi-frequency LCR-meter at frequencies ranging from 100 Hz to 100 k Hz, the device was calibrated at 100 Hz against the moisture air over the range of 30-85 % RH, which includes normal humidity level in the atmosphere and physiologic air such as breath and sweating. The response sensitivity of the conductimetric device was extremely high (i.e. less than 1 sec. for conductivity shift between humid air of 80 % RH and dried air of -60 /spl deg/C dew point) even for recovery to dried air. The sensor performance was reproducible over multiple measurements, showing the highly reproducibility with a coefficient of variation of 1.77 % (n = 5).\",\"PeriodicalId\":129668,\"journal\":{\"name\":\"2002 Conference on Optoelectronic and Microelectronic Materials and Devices. COMMAD 2002. Proceedings (Cat. No.02EX601)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 Conference on Optoelectronic and Microelectronic Materials and Devices. COMMAD 2002. Proceedings (Cat. No.02EX601)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COMMAD.2002.1237231\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 Conference on Optoelectronic and Microelectronic Materials and Devices. COMMAD 2002. Proceedings (Cat. No.02EX601)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMMAD.2002.1237231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在两个金沉积层之间放置亲水性聚四氟乙烯膜,在夹层结构中构建导电传感器(厚度:80 /spl μ m /m),评估其作为湿度传感器的用途。湿度水平通过设备的电导率测量,使用多频LCR-meter在100 Hz至100 k Hz的频率范围内测量,该设备在100 Hz下针对30- 85% RH范围内的潮湿空气进行校准,其中包括大气中的正常湿度水平和生理空气(如呼吸和出汗)。电导装置的响应灵敏度非常高(即,在80% RH的潮湿空气和-60 /spl℃露点的干燥空气之间的电导率变化小于1秒),即使恢复到干燥空气。该传感器的性能可重复多次测量,重复性高,变异系数为1.77% (n = 5)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electric conductimetric sensor with a thin-layer structure for moisture analysis
An electric conductimetric sensor (thickness: 80 /spl mu/m) constructed in a sandwich configuration with a hydrophilic poly-tetrafluoroethylene membrane placed between two gold deposited layers was evaluated for use as a moisture sensor. The humidity level was measured by electrical conductivity of the device using the Multi-frequency LCR-meter at frequencies ranging from 100 Hz to 100 k Hz, the device was calibrated at 100 Hz against the moisture air over the range of 30-85 % RH, which includes normal humidity level in the atmosphere and physiologic air such as breath and sweating. The response sensitivity of the conductimetric device was extremely high (i.e. less than 1 sec. for conductivity shift between humid air of 80 % RH and dried air of -60 /spl deg/C dew point) even for recovery to dried air. The sensor performance was reproducible over multiple measurements, showing the highly reproducibility with a coefficient of variation of 1.77 % (n = 5).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信