M Böck, S Himmelsbach, A Gudden, L Greither, W Mempel
{"title":"[白细胞减少的血小板浓缩物的制备:一种新型过滤系统的体外测试(PL 100)]。","authors":"M Böck, S Himmelsbach, A Gudden, L Greither, W Mempel","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A newly developed filter-system (PL 100) for the removal of leukocytes from platelet concentrates was tested. It removes contaminating leukocytes by 99.7 +/- 0.6%. The platelet loss was calculated as 25.7 +/- 9.5%. The filtration process does not influence the filtered platelets; plasma-electrolytes, LDH-concentrations, platelet aggregation curves and serotonin-release remain constant. In addition, platelet ultrastructure is not influenced by the filtration. In spite of the high platelet loss, the tested filter-system seems to be a suitable alternative to the conventional methods for the removal of contaminating leukocytes from platelet concentrates.</p>","PeriodicalId":77545,"journal":{"name":"Infusionstherapie (Basel, Switzerland)","volume":"18 1","pages":"30-2"},"PeriodicalIF":0.0000,"publicationDate":"1991-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Preparation of leukocyte-depleted thrombocyte concentrate: in-vitro testing of a new filtration system (PL 100)].\",\"authors\":\"M Böck, S Himmelsbach, A Gudden, L Greither, W Mempel\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A newly developed filter-system (PL 100) for the removal of leukocytes from platelet concentrates was tested. It removes contaminating leukocytes by 99.7 +/- 0.6%. The platelet loss was calculated as 25.7 +/- 9.5%. The filtration process does not influence the filtered platelets; plasma-electrolytes, LDH-concentrations, platelet aggregation curves and serotonin-release remain constant. In addition, platelet ultrastructure is not influenced by the filtration. In spite of the high platelet loss, the tested filter-system seems to be a suitable alternative to the conventional methods for the removal of contaminating leukocytes from platelet concentrates.</p>\",\"PeriodicalId\":77545,\"journal\":{\"name\":\"Infusionstherapie (Basel, Switzerland)\",\"volume\":\"18 1\",\"pages\":\"30-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infusionstherapie (Basel, Switzerland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infusionstherapie (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Preparation of leukocyte-depleted thrombocyte concentrate: in-vitro testing of a new filtration system (PL 100)].
A newly developed filter-system (PL 100) for the removal of leukocytes from platelet concentrates was tested. It removes contaminating leukocytes by 99.7 +/- 0.6%. The platelet loss was calculated as 25.7 +/- 9.5%. The filtration process does not influence the filtered platelets; plasma-electrolytes, LDH-concentrations, platelet aggregation curves and serotonin-release remain constant. In addition, platelet ultrastructure is not influenced by the filtration. In spite of the high platelet loss, the tested filter-system seems to be a suitable alternative to the conventional methods for the removal of contaminating leukocytes from platelet concentrates.