向上负阶跃引线的电场特性

M. Azadifar, F. Rachidi, M. Rubinstein, M. Paolone, V. Rakov, D. Pavanello, S. Metz, C. Romero
{"title":"向上负阶跃引线的电场特性","authors":"M. Azadifar, F. Rachidi, M. Rubinstein, M. Paolone, V. Rakov, D. Pavanello, S. Metz, C. Romero","doi":"10.1109/SIPDA.2015.7339279","DOIUrl":null,"url":null,"abstract":"We report simultaneous measurements of vertical electric fields and currents associated with positive flashes to the Säntis tower. The fields were measured at a distance of 14.7 km from the tower. All the data correspond to type-2 positive flashes characterized by currents with relatively slow rising portion on which oscillatory pulse trains, inferred to be due to an upward negative stepped leader, are superimposed. Bipolar electric field and current pulses associated with the upward negative stepped leader are examined and analyzed. The widths of the initial and second half cycles are found to be similar. The peak of the initial half cycle is found to be, on average, about twice as high as the peak of the second half cycle. A nearly linear correlation is found between the field peaks and associated current peaks.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"95 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Characteristics of electric fields of upward negative stepped leaders\",\"authors\":\"M. Azadifar, F. Rachidi, M. Rubinstein, M. Paolone, V. Rakov, D. Pavanello, S. Metz, C. Romero\",\"doi\":\"10.1109/SIPDA.2015.7339279\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report simultaneous measurements of vertical electric fields and currents associated with positive flashes to the Säntis tower. The fields were measured at a distance of 14.7 km from the tower. All the data correspond to type-2 positive flashes characterized by currents with relatively slow rising portion on which oscillatory pulse trains, inferred to be due to an upward negative stepped leader, are superimposed. Bipolar electric field and current pulses associated with the upward negative stepped leader are examined and analyzed. The widths of the initial and second half cycles are found to be similar. The peak of the initial half cycle is found to be, on average, about twice as high as the peak of the second half cycle. A nearly linear correlation is found between the field peaks and associated current peaks.\",\"PeriodicalId\":296478,\"journal\":{\"name\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"volume\":\"95 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Symposium on Lightning Protection (XIII SIPDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2015.7339279\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

我们同时向Säntis塔报告垂直电场和与正闪光相关的电流的测量结果。这些田地是在距离塔14.7公里处测量的。所有数据都对应于2型正闪,其特征是电流具有相对缓慢的上升部分,在其上叠加振荡脉冲序列,推断是由于向上的负阶跃先导引起的。研究并分析了与向上负阶跃引线相关的双极电场和电流脉冲。发现初始半周期和后半周期的宽度相似。发现初始半周期的峰值平均约为后半周期峰值的两倍。在场峰和相关的电流峰之间发现了近似线性的相关关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics of electric fields of upward negative stepped leaders
We report simultaneous measurements of vertical electric fields and currents associated with positive flashes to the Säntis tower. The fields were measured at a distance of 14.7 km from the tower. All the data correspond to type-2 positive flashes characterized by currents with relatively slow rising portion on which oscillatory pulse trains, inferred to be due to an upward negative stepped leader, are superimposed. Bipolar electric field and current pulses associated with the upward negative stepped leader are examined and analyzed. The widths of the initial and second half cycles are found to be similar. The peak of the initial half cycle is found to be, on average, about twice as high as the peak of the second half cycle. A nearly linear correlation is found between the field peaks and associated current peaks.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信