基于电导的RTP系统的晶圆温度测量

E. Granneman, X. Pagès, K. Vanormelingen, P. Vermont
{"title":"基于电导的RTP系统的晶圆温度测量","authors":"E. Granneman, X. Pagès, K. Vanormelingen, P. Vermont","doi":"10.1109/RTP.2008.4690566","DOIUrl":null,"url":null,"abstract":"In conduction-based RTP systems the heating relies on the conduction of energy through a thin gas layer of gas between the wafer and the surrounding chamber walls. In most of these types of systems a gas flow is used to control the heating ambient. It turns out that the pressure drop in the system is a direct measure of the wafer temperature. This principle is used to determine the wafer temperature in the Levitor system. With this method, temperature measurements can be carried out in the range 200–1100°C. The absolute accuracy and repeatability in steady state (i.e. long processing times) is 4°C and 1.5°C (1σ), respectively. The time resolution is in the ms range. Transient phenomena that influence the measurements in short anneal processes are discussed in detail, and procedures are given to correct for such effects.","PeriodicalId":317927,"journal":{"name":"2008 16th IEEE International Conference on Advanced Thermal Processing of Semiconductors","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wafer temperature measurement in conduction-based RTP systems\",\"authors\":\"E. Granneman, X. Pagès, K. Vanormelingen, P. Vermont\",\"doi\":\"10.1109/RTP.2008.4690566\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In conduction-based RTP systems the heating relies on the conduction of energy through a thin gas layer of gas between the wafer and the surrounding chamber walls. In most of these types of systems a gas flow is used to control the heating ambient. It turns out that the pressure drop in the system is a direct measure of the wafer temperature. This principle is used to determine the wafer temperature in the Levitor system. With this method, temperature measurements can be carried out in the range 200–1100°C. The absolute accuracy and repeatability in steady state (i.e. long processing times) is 4°C and 1.5°C (1σ), respectively. The time resolution is in the ms range. Transient phenomena that influence the measurements in short anneal processes are discussed in detail, and procedures are given to correct for such effects.\",\"PeriodicalId\":317927,\"journal\":{\"name\":\"2008 16th IEEE International Conference on Advanced Thermal Processing of Semiconductors\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 16th IEEE International Conference on Advanced Thermal Processing of Semiconductors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RTP.2008.4690566\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 16th IEEE International Conference on Advanced Thermal Processing of Semiconductors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTP.2008.4690566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在基于传导的RTP系统中,加热依赖于通过晶圆片和周围腔壁之间的薄气体层的能量传导。在大多数这类系统中,气流是用来控制加热环境的。结果表明,系统中的压降是晶圆温度的直接度量。这个原理被用来确定Levitor系统中的晶圆温度。使用这种方法,可以在200-1100°C范围内进行温度测量。稳态(即长处理时间)下的绝对精度和可重复性分别为4°C和1.5°C (1σ)。时间分辨率以毫秒为单位。详细讨论了在短退火过程中影响测量的瞬态现象,并给出了纠正这种影响的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wafer temperature measurement in conduction-based RTP systems
In conduction-based RTP systems the heating relies on the conduction of energy through a thin gas layer of gas between the wafer and the surrounding chamber walls. In most of these types of systems a gas flow is used to control the heating ambient. It turns out that the pressure drop in the system is a direct measure of the wafer temperature. This principle is used to determine the wafer temperature in the Levitor system. With this method, temperature measurements can be carried out in the range 200–1100°C. The absolute accuracy and repeatability in steady state (i.e. long processing times) is 4°C and 1.5°C (1σ), respectively. The time resolution is in the ms range. Transient phenomena that influence the measurements in short anneal processes are discussed in detail, and procedures are given to correct for such effects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信