{"title":"无创血糖测量近红外光学测量的应用","authors":"M. N. Anas, A. Syafirah, A. N. Norali, M. Normahira","doi":"10.1109/STUDENT.2012.6408415","DOIUrl":null,"url":null,"abstract":"In clinical practice currently, blood glucose is measured using an invasive techniques which is unsuitable and having risky of infection in the patient since the finger is pricked three to five times a day. In this study, near infrared optical measurement is applied to overcome the invasive issues. The designed device consists of an infrared emitter which placed over the fingertip for measurement of blood glucose optically. The near-infrared light will be sensed by the photo diode which having a certain wavelength. The intensity of received light is depending on the glucose molecules inside the blood. Tensubjects have been used during the experiment set. Early result is presented that blood-glucose level range starting from 6.3 to 11.5mol/L during normal non-fasting, voltage measured from the design device having of 1.4V to 1.66V and during fasting, the voltage range is about 1.38V to 1.61 V with reading of 4.7 to 5.5 mol/L. The prediction of blood glucose reading for 10 subjects also is presented.","PeriodicalId":282263,"journal":{"name":"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)","volume":"13 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Non-invasive blood glucose measurement Application of near infrared optical measurement\",\"authors\":\"M. N. Anas, A. Syafirah, A. N. Norali, M. Normahira\",\"doi\":\"10.1109/STUDENT.2012.6408415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In clinical practice currently, blood glucose is measured using an invasive techniques which is unsuitable and having risky of infection in the patient since the finger is pricked three to five times a day. In this study, near infrared optical measurement is applied to overcome the invasive issues. The designed device consists of an infrared emitter which placed over the fingertip for measurement of blood glucose optically. The near-infrared light will be sensed by the photo diode which having a certain wavelength. The intensity of received light is depending on the glucose molecules inside the blood. Tensubjects have been used during the experiment set. Early result is presented that blood-glucose level range starting from 6.3 to 11.5mol/L during normal non-fasting, voltage measured from the design device having of 1.4V to 1.66V and during fasting, the voltage range is about 1.38V to 1.61 V with reading of 4.7 to 5.5 mol/L. The prediction of blood glucose reading for 10 subjects also is presented.\",\"PeriodicalId\":282263,\"journal\":{\"name\":\"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)\",\"volume\":\"13 8\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STUDENT.2012.6408415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STUDENT.2012.6408415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Non-invasive blood glucose measurement Application of near infrared optical measurement
In clinical practice currently, blood glucose is measured using an invasive techniques which is unsuitable and having risky of infection in the patient since the finger is pricked three to five times a day. In this study, near infrared optical measurement is applied to overcome the invasive issues. The designed device consists of an infrared emitter which placed over the fingertip for measurement of blood glucose optically. The near-infrared light will be sensed by the photo diode which having a certain wavelength. The intensity of received light is depending on the glucose molecules inside the blood. Tensubjects have been used during the experiment set. Early result is presented that blood-glucose level range starting from 6.3 to 11.5mol/L during normal non-fasting, voltage measured from the design device having of 1.4V to 1.66V and during fasting, the voltage range is about 1.38V to 1.61 V with reading of 4.7 to 5.5 mol/L. The prediction of blood glucose reading for 10 subjects also is presented.