{"title":"基于功率方向考虑反向保护的点网光伏承载容量评估方法","authors":"Z. Zhihua, Zhao Yi-long, Wang Kun","doi":"10.1109/iSPEC50848.2020.9350951","DOIUrl":null,"url":null,"abstract":"Compared to traditional method, the improved reverse power protection method that based on current variation and positive sequence power direction could enhance the photovoltaic (PV) hosting capacity greatly in a spot network. However, how to calculate the value of PV hosting capacity with the improved reverse power protection has not been discussed. This paper presents a method about how to assess the PV hosting capacity in a spot network with the improved re-verse power protection. Considering the output current characteristics of a PV inverter under external fault, a composite sequence network under types of short circuit fault is analyzed. The relationship between the setting value of protection and the access current of PV is deduced. By studying the critical condition of protection failure, a method of assessing PV hosting capacity to avoid protection misoperation is proposed. The simulation model based on practical engineering by PSCAD is established. And simulation results verify the correctness of this assessment method. By modeling and simulation, the influence of load, fault tran-sition, and load imbalance on PV hosting capacity are analyzed.","PeriodicalId":403879,"journal":{"name":"2020 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Method of Assessing Photovoltaic Hosting Capacity Considering reverse power protection based on power direction in a Spot Network\",\"authors\":\"Z. Zhihua, Zhao Yi-long, Wang Kun\",\"doi\":\"10.1109/iSPEC50848.2020.9350951\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Compared to traditional method, the improved reverse power protection method that based on current variation and positive sequence power direction could enhance the photovoltaic (PV) hosting capacity greatly in a spot network. However, how to calculate the value of PV hosting capacity with the improved reverse power protection has not been discussed. This paper presents a method about how to assess the PV hosting capacity in a spot network with the improved re-verse power protection. Considering the output current characteristics of a PV inverter under external fault, a composite sequence network under types of short circuit fault is analyzed. The relationship between the setting value of protection and the access current of PV is deduced. By studying the critical condition of protection failure, a method of assessing PV hosting capacity to avoid protection misoperation is proposed. The simulation model based on practical engineering by PSCAD is established. And simulation results verify the correctness of this assessment method. By modeling and simulation, the influence of load, fault tran-sition, and load imbalance on PV hosting capacity are analyzed.\",\"PeriodicalId\":403879,\"journal\":{\"name\":\"2020 IEEE Sustainable Power and Energy Conference (iSPEC)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Sustainable Power and Energy Conference (iSPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/iSPEC50848.2020.9350951\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Sustainable Power and Energy Conference (iSPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iSPEC50848.2020.9350951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Method of Assessing Photovoltaic Hosting Capacity Considering reverse power protection based on power direction in a Spot Network
Compared to traditional method, the improved reverse power protection method that based on current variation and positive sequence power direction could enhance the photovoltaic (PV) hosting capacity greatly in a spot network. However, how to calculate the value of PV hosting capacity with the improved reverse power protection has not been discussed. This paper presents a method about how to assess the PV hosting capacity in a spot network with the improved re-verse power protection. Considering the output current characteristics of a PV inverter under external fault, a composite sequence network under types of short circuit fault is analyzed. The relationship between the setting value of protection and the access current of PV is deduced. By studying the critical condition of protection failure, a method of assessing PV hosting capacity to avoid protection misoperation is proposed. The simulation model based on practical engineering by PSCAD is established. And simulation results verify the correctness of this assessment method. By modeling and simulation, the influence of load, fault tran-sition, and load imbalance on PV hosting capacity are analyzed.