{"title":"核电站测试数据采集的趋势","authors":"J. Mazalerat, J. Favennec","doi":"10.1109/CMPEUR.1989.93423","DOIUrl":null,"url":null,"abstract":"Electricite de France (EDF), the French electric utility, performs extensive testing on its nuclear power plants for commissioning needs or optimization purposes. The required instrumentation must meet demanding metrological, functional, and technological specifications. Smart sensors are a significant step in instrumentation. They provide higher accuracy of measurement, identification and validation of information, and consistent data. The authors described EDF's strategy for the architecture, power supply, communication, and configuration of smart sensor systems for testing needs. Tests performed on the Saint Alban power plant demonstrate the feasibility of the distributed consumption test-system concept, which allows decentralization of measurement acquisition and estimation of the amount of money saved by reduced wiring.<<ETX>>","PeriodicalId":304457,"journal":{"name":"Proceedings. VLSI and Computer Peripherals. COMPEURO 89","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Trends in data acquisition for testing in nuclear power stations\",\"authors\":\"J. Mazalerat, J. Favennec\",\"doi\":\"10.1109/CMPEUR.1989.93423\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electricite de France (EDF), the French electric utility, performs extensive testing on its nuclear power plants for commissioning needs or optimization purposes. The required instrumentation must meet demanding metrological, functional, and technological specifications. Smart sensors are a significant step in instrumentation. They provide higher accuracy of measurement, identification and validation of information, and consistent data. The authors described EDF's strategy for the architecture, power supply, communication, and configuration of smart sensor systems for testing needs. Tests performed on the Saint Alban power plant demonstrate the feasibility of the distributed consumption test-system concept, which allows decentralization of measurement acquisition and estimation of the amount of money saved by reduced wiring.<<ETX>>\",\"PeriodicalId\":304457,\"journal\":{\"name\":\"Proceedings. VLSI and Computer Peripherals. COMPEURO 89\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-05-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. VLSI and Computer Peripherals. COMPEURO 89\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CMPEUR.1989.93423\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. VLSI and Computer Peripherals. COMPEURO 89","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMPEUR.1989.93423","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

法国电力公司(EDF)对其核电站进行了广泛的测试,以满足调试需求或优化目的。所需的仪器必须满足严格的计量、功能和技术规范。智能传感器是仪器仪表发展的重要一步。它们提供了更高的测量精度、信息识别和验证以及一致的数据。作者描述了EDF的架构、电源、通信和智能传感器系统配置策略,以满足测试需求。在圣阿尔班发电厂进行的测试证明了分布式消耗测试系统概念的可行性,该概念允许分散测量获取和减少布线所节省的金额的估计
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Trends in data acquisition for testing in nuclear power stations
Electricite de France (EDF), the French electric utility, performs extensive testing on its nuclear power plants for commissioning needs or optimization purposes. The required instrumentation must meet demanding metrological, functional, and technological specifications. Smart sensors are a significant step in instrumentation. They provide higher accuracy of measurement, identification and validation of information, and consistent data. The authors described EDF's strategy for the architecture, power supply, communication, and configuration of smart sensor systems for testing needs. Tests performed on the Saint Alban power plant demonstrate the feasibility of the distributed consumption test-system concept, which allows decentralization of measurement acquisition and estimation of the amount of money saved by reduced wiring.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信