Marc Martínez-Estrada, R. Fernández-García, I. Gil
{"title":"基于纺织传感器的可穿戴尿液泄漏检测系统。","authors":"Marc Martínez-Estrada, R. Fernández-García, I. Gil","doi":"10.1109/FLEPS49123.2020.9239554","DOIUrl":null,"url":null,"abstract":"In this work, a wearable system to detect urine leakage based on a textile sensor is proposed. The system consists of a capacitive sensor embroidered with a conductive yarn in a cotton/polyester substrate. A microcontroller (MCU) with a wireless module for signal acquisition and a smartphone for monitoring complete the overall system. The capacitive sensor behaviour was tested in a climatic chamber between 30 % and 80% of relative humidity (RH) with a LCR meter and charge/discharge method directly connected to the MCU. The results show that the proposed system is able to detect urine leakage even though when the patient wears a diaper. The functionally allows to develop a real time monitoring system which can help nursing and medical assistants to take care of elderly and disabled people and improve the quality of life of these patients.","PeriodicalId":101496,"journal":{"name":"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A wearable system to detect urine leakage based on a textile sensor.\",\"authors\":\"Marc Martínez-Estrada, R. Fernández-García, I. Gil\",\"doi\":\"10.1109/FLEPS49123.2020.9239554\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, a wearable system to detect urine leakage based on a textile sensor is proposed. The system consists of a capacitive sensor embroidered with a conductive yarn in a cotton/polyester substrate. A microcontroller (MCU) with a wireless module for signal acquisition and a smartphone for monitoring complete the overall system. The capacitive sensor behaviour was tested in a climatic chamber between 30 % and 80% of relative humidity (RH) with a LCR meter and charge/discharge method directly connected to the MCU. The results show that the proposed system is able to detect urine leakage even though when the patient wears a diaper. The functionally allows to develop a real time monitoring system which can help nursing and medical assistants to take care of elderly and disabled people and improve the quality of life of these patients.\",\"PeriodicalId\":101496,\"journal\":{\"name\":\"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)\",\"volume\":\"115 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FLEPS49123.2020.9239554\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FLEPS49123.2020.9239554","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A wearable system to detect urine leakage based on a textile sensor.
In this work, a wearable system to detect urine leakage based on a textile sensor is proposed. The system consists of a capacitive sensor embroidered with a conductive yarn in a cotton/polyester substrate. A microcontroller (MCU) with a wireless module for signal acquisition and a smartphone for monitoring complete the overall system. The capacitive sensor behaviour was tested in a climatic chamber between 30 % and 80% of relative humidity (RH) with a LCR meter and charge/discharge method directly connected to the MCU. The results show that the proposed system is able to detect urine leakage even though when the patient wears a diaper. The functionally allows to develop a real time monitoring system which can help nursing and medical assistants to take care of elderly and disabled people and improve the quality of life of these patients.