A. Berdnikov, V. Kapralov, K. Solovyev, N. Krasnova
{"title":"周期供电电压离子光学系统中带电粒子的多维稳定域构造算法","authors":"A. Berdnikov, V. Kapralov, K. Solovyev, N. Krasnova","doi":"10.1109/EExPolytech53083.2021.9614739","DOIUrl":null,"url":null,"abstract":"Some mass separating systems use ion optics with periodic supply voltage to separate ions for mass-to-charge ratio. The equation of motion should be linear to guarantee that there is no dependence of stability on initial conditions. To get mass spectrometer stability zone it is possible to overlay stability diagrams of all equations, which are Hill-type ones. Another way to solve this problem when ion equations are not separated is suggested.","PeriodicalId":141827,"journal":{"name":"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Algorithm for Constructing a Multidimensional Stability Domain of a Charged Particle in an Ion-Optical System with Periodic Supply Voltage\",\"authors\":\"A. Berdnikov, V. Kapralov, K. Solovyev, N. Krasnova\",\"doi\":\"10.1109/EExPolytech53083.2021.9614739\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Some mass separating systems use ion optics with periodic supply voltage to separate ions for mass-to-charge ratio. The equation of motion should be linear to guarantee that there is no dependence of stability on initial conditions. To get mass spectrometer stability zone it is possible to overlay stability diagrams of all equations, which are Hill-type ones. Another way to solve this problem when ion equations are not separated is suggested.\",\"PeriodicalId\":141827,\"journal\":{\"name\":\"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EExPolytech53083.2021.9614739\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Engineering and Photonics (EExPolytech)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EExPolytech53083.2021.9614739","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Algorithm for Constructing a Multidimensional Stability Domain of a Charged Particle in an Ion-Optical System with Periodic Supply Voltage
Some mass separating systems use ion optics with periodic supply voltage to separate ions for mass-to-charge ratio. The equation of motion should be linear to guarantee that there is no dependence of stability on initial conditions. To get mass spectrometer stability zone it is possible to overlay stability diagrams of all equations, which are Hill-type ones. Another way to solve this problem when ion equations are not separated is suggested.