{"title":"一种快速去除继电器输入电流中衰减偏置的新方法","authors":"E. Rosolowski","doi":"10.1109/EPE58302.2023.10149233","DOIUrl":null,"url":null,"abstract":"Phasor estimation is still the primary method of high-speed measurements used in electrical power system protection and control. Widely applied filter algorithms are based on the discrete Fourier transform (DFT), which can easily erase harmonics. However, the voltage and current waveforms that accompany short circuits in the network contain both harmonic components and decaying DC (DDC) components. Various methods of reducing the effect of the decaying aperiodic component on the accuracy of determining the amplitude and phase of the current’s fundamental component have been proposed for decades. Judging from recent publications, the issue is still relevant. The presented method proposes to change the known paradigm by including a modified signal model in the transition state of the algorithm with an expanding measurement window. The measured signal is shown to be represented by the sum of the orthogonal components of the corresponding harmonics and the mapping of the DDC components. The simulation studies conducted show the properties of the presented method.","PeriodicalId":210548,"journal":{"name":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A New Method for Fast Removal of Decaying Offset in Relaying Input Current\",\"authors\":\"E. Rosolowski\",\"doi\":\"10.1109/EPE58302.2023.10149233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Phasor estimation is still the primary method of high-speed measurements used in electrical power system protection and control. Widely applied filter algorithms are based on the discrete Fourier transform (DFT), which can easily erase harmonics. However, the voltage and current waveforms that accompany short circuits in the network contain both harmonic components and decaying DC (DDC) components. Various methods of reducing the effect of the decaying aperiodic component on the accuracy of determining the amplitude and phase of the current’s fundamental component have been proposed for decades. Judging from recent publications, the issue is still relevant. The presented method proposes to change the known paradigm by including a modified signal model in the transition state of the algorithm with an expanding measurement window. The measured signal is shown to be represented by the sum of the orthogonal components of the corresponding harmonics and the mapping of the DDC components. The simulation studies conducted show the properties of the presented method.\",\"PeriodicalId\":210548,\"journal\":{\"name\":\"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE58302.2023.10149233\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE58302.2023.10149233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

相量估计仍然是电力系统保护和控制中高速测量的主要方法。广泛应用的滤波算法是基于离散傅立叶变换(DFT),它可以很容易地消除谐波。然而,伴随着网络短路的电压和电流波形同时包含谐波分量和衰减的直流(DDC)分量。几十年来,人们提出了各种方法来降低衰减的非周期分量对确定电流基本分量的幅度和相位精度的影响。从最近的出版物来看,这个问题仍然具有相关性。该方法通过在算法的过渡状态中加入一个改进的信号模型来改变已知的范式,该模型具有扩展的测量窗口。被测信号由相应谐波的正交分量和DDC分量的映射表示。仿真研究表明了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A New Method for Fast Removal of Decaying Offset in Relaying Input Current
Phasor estimation is still the primary method of high-speed measurements used in electrical power system protection and control. Widely applied filter algorithms are based on the discrete Fourier transform (DFT), which can easily erase harmonics. However, the voltage and current waveforms that accompany short circuits in the network contain both harmonic components and decaying DC (DDC) components. Various methods of reducing the effect of the decaying aperiodic component on the accuracy of determining the amplitude and phase of the current’s fundamental component have been proposed for decades. Judging from recent publications, the issue is still relevant. The presented method proposes to change the known paradigm by including a modified signal model in the transition state of the algorithm with an expanding measurement window. The measured signal is shown to be represented by the sum of the orthogonal components of the corresponding harmonics and the mapping of the DDC components. The simulation studies conducted show the properties of the presented method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信