封闭设备外部的电弧闪光暴露

Clinton Carne, Henry Hank Clark, Michael McConnell
{"title":"封闭设备外部的电弧闪光暴露","authors":"Clinton Carne, Henry Hank Clark, Michael McConnell","doi":"10.1109/PCIC42668.2022.10181281","DOIUrl":null,"url":null,"abstract":"Current standards have made good progress in helping engineers calculate the incident energy a worker would be exposed to when bare energized conductors are present. However, there are no alternate calculation methods or adjustment factors available to quantify the effects of equipment enclosures, or other conditions where a user maybe indirectly exposed to an internal arcing fault. IEEE C37.20.7, which sets criteria for Arc Resistant Switchgear, does not directly establish potential incident energy exposure levels outside the equipment under test. UL RP 2986 does begin to lay groundwork to quantify incident energy levels outside of enclosed equipment including instrumentation and testing parameters. However, it does not clearly define how to apply said procedures. This paper will address selection of appropriate parameters based on experience with testing low-voltage distribution equipment to the UL RP 2986 practice. Selected test results will be compared with the results of IEEE 1584-2018 calculations. The paper will also discuss the benefits of tested equipment that has been examined to measure the actual incident energy levels outside of enclosed equipment, including identifying situations where a worker may be shielded from incident energy levels greater than 1.2 cal/cm2.","PeriodicalId":301848,"journal":{"name":"2022 IEEE IAS Petroleum and Chemical Industry Technical Conference (PCIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ARC Flash Exposure Outside of Enclosed Equipment\",\"authors\":\"Clinton Carne, Henry Hank Clark, Michael McConnell\",\"doi\":\"10.1109/PCIC42668.2022.10181281\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Current standards have made good progress in helping engineers calculate the incident energy a worker would be exposed to when bare energized conductors are present. However, there are no alternate calculation methods or adjustment factors available to quantify the effects of equipment enclosures, or other conditions where a user maybe indirectly exposed to an internal arcing fault. IEEE C37.20.7, which sets criteria for Arc Resistant Switchgear, does not directly establish potential incident energy exposure levels outside the equipment under test. UL RP 2986 does begin to lay groundwork to quantify incident energy levels outside of enclosed equipment including instrumentation and testing parameters. However, it does not clearly define how to apply said procedures. This paper will address selection of appropriate parameters based on experience with testing low-voltage distribution equipment to the UL RP 2986 practice. Selected test results will be compared with the results of IEEE 1584-2018 calculations. The paper will also discuss the benefits of tested equipment that has been examined to measure the actual incident energy levels outside of enclosed equipment, including identifying situations where a worker may be shielded from incident energy levels greater than 1.2 cal/cm2.\",\"PeriodicalId\":301848,\"journal\":{\"name\":\"2022 IEEE IAS Petroleum and Chemical Industry Technical Conference (PCIC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE IAS Petroleum and Chemical Industry Technical Conference (PCIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCIC42668.2022.10181281\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE IAS Petroleum and Chemical Industry Technical Conference (PCIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCIC42668.2022.10181281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前的标准在帮助工程师计算裸露的通电导体存在时工人所暴露的入射能量方面取得了很好的进展。然而,没有替代的计算方法或调整因素可用于量化设备外壳的影响,或用户可能间接暴露于内部电弧故障的其他条件。IEEE C37.20.7设定了抗电弧开关设备的标准,但并未直接建立被测设备外部的潜在入射能量暴露水平。UL RP 2986确实开始为量化封闭设备(包括仪器和测试参数)之外的入射能级奠定基础。但是,它没有明确规定如何适用上述程序。本文将根据测试低压配电设备以符合UL RP 2986规范的经验,讨论如何选择合适的参数。选择的测试结果将与IEEE 1584-2018计算结果进行比较。本文还将讨论测试设备的好处,这些设备已被检查以测量封闭设备外的实际入射能量水平,包括确定工人可能被屏蔽的入射能量水平大于1.2 cal/cm2的情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ARC Flash Exposure Outside of Enclosed Equipment
Current standards have made good progress in helping engineers calculate the incident energy a worker would be exposed to when bare energized conductors are present. However, there are no alternate calculation methods or adjustment factors available to quantify the effects of equipment enclosures, or other conditions where a user maybe indirectly exposed to an internal arcing fault. IEEE C37.20.7, which sets criteria for Arc Resistant Switchgear, does not directly establish potential incident energy exposure levels outside the equipment under test. UL RP 2986 does begin to lay groundwork to quantify incident energy levels outside of enclosed equipment including instrumentation and testing parameters. However, it does not clearly define how to apply said procedures. This paper will address selection of appropriate parameters based on experience with testing low-voltage distribution equipment to the UL RP 2986 practice. Selected test results will be compared with the results of IEEE 1584-2018 calculations. The paper will also discuss the benefits of tested equipment that has been examined to measure the actual incident energy levels outside of enclosed equipment, including identifying situations where a worker may be shielded from incident energy levels greater than 1.2 cal/cm2.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信