{"title":"北方燃气公司冷却系统中水的回用","authors":"Khasraw S. Ali, Saif T. Manji, M. H. Zangana","doi":"10.1109/EIOGI.2017.8267632","DOIUrl":null,"url":null,"abstract":"Increasing and expanding oil and gas processing was accompanied by high demand on water. As a crucial element for both life and agriculture, water sources have to be kept unpolluted and preserved from the pollutant and high consumption from such industries. Thus, came to exist water re-use. Before water re-use can be optimized within a natural gas processing facility, all process water streams and utility water streams must be considered to operate in an integrated fashion that minimizes the water intake and discharge. and water treatment. The cooling system in the North Gas Company is the most demanding unit in terms of water requirement. In this research a water treatment unit is proposed to eliminate and reduce water and pollutants discharged to the Zab channel and well as minimize the water intake to the North Gas Company. For this purpose, an RO units are designed to treat the effluents and the makeup water using IMSDesign 2017 provided by Hydranautics. The optimum membrane type was found to be CPA6 MAX; a brackish water high rejection membrane that has a production rate of 8800 gallon/day and 440 ft2 area.","PeriodicalId":285569,"journal":{"name":"2017 International Conference on Environmental Impacts of the Oil and Gas Industries: Kurdistan Region of Iraq as a Case Study (EIOGI)","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Water reuse in cooling system at North Gas Company\",\"authors\":\"Khasraw S. Ali, Saif T. Manji, M. H. Zangana\",\"doi\":\"10.1109/EIOGI.2017.8267632\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Increasing and expanding oil and gas processing was accompanied by high demand on water. As a crucial element for both life and agriculture, water sources have to be kept unpolluted and preserved from the pollutant and high consumption from such industries. Thus, came to exist water re-use. Before water re-use can be optimized within a natural gas processing facility, all process water streams and utility water streams must be considered to operate in an integrated fashion that minimizes the water intake and discharge. and water treatment. The cooling system in the North Gas Company is the most demanding unit in terms of water requirement. In this research a water treatment unit is proposed to eliminate and reduce water and pollutants discharged to the Zab channel and well as minimize the water intake to the North Gas Company. For this purpose, an RO units are designed to treat the effluents and the makeup water using IMSDesign 2017 provided by Hydranautics. The optimum membrane type was found to be CPA6 MAX; a brackish water high rejection membrane that has a production rate of 8800 gallon/day and 440 ft2 area.\",\"PeriodicalId\":285569,\"journal\":{\"name\":\"2017 International Conference on Environmental Impacts of the Oil and Gas Industries: Kurdistan Region of Iraq as a Case Study (EIOGI)\",\"volume\":\"96 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Environmental Impacts of the Oil and Gas Industries: Kurdistan Region of Iraq as a Case Study (EIOGI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIOGI.2017.8267632\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Environmental Impacts of the Oil and Gas Industries: Kurdistan Region of Iraq as a Case Study (EIOGI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIOGI.2017.8267632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

石油和天然气加工的增加和扩大伴随着对水的高需求。作为生命和农业的关键因素,水源必须保持不受污染,不受这些工业的污染和高消耗的影响。于是,就有了水的再利用。在优化天然气处理设施内的水再利用之前,必须考虑所有工艺水流和公用事业水流以一种集成的方式运行,以最大限度地减少水的摄入和排放。还有水处理。北方燃气公司的冷却系统是用水要求最高的单位。本研究提出了一种水处理装置,以消除和减少排放到Zab通道的水和污染物,并最大限度地减少北方天然气公司的取水量。为此,使用Hydranautics提供的IMSDesign 2017,设计了一个RO单元来处理废水和补给水。最佳膜型为CPA6 MAX;一种生产速率为8800加仑/天,面积440平方英尺的微咸水高阻膜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Water reuse in cooling system at North Gas Company
Increasing and expanding oil and gas processing was accompanied by high demand on water. As a crucial element for both life and agriculture, water sources have to be kept unpolluted and preserved from the pollutant and high consumption from such industries. Thus, came to exist water re-use. Before water re-use can be optimized within a natural gas processing facility, all process water streams and utility water streams must be considered to operate in an integrated fashion that minimizes the water intake and discharge. and water treatment. The cooling system in the North Gas Company is the most demanding unit in terms of water requirement. In this research a water treatment unit is proposed to eliminate and reduce water and pollutants discharged to the Zab channel and well as minimize the water intake to the North Gas Company. For this purpose, an RO units are designed to treat the effluents and the makeup water using IMSDesign 2017 provided by Hydranautics. The optimum membrane type was found to be CPA6 MAX; a brackish water high rejection membrane that has a production rate of 8800 gallon/day and 440 ft2 area.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信