用于周围血管疾病评估的高分辨率三维光声扫描仪的临床评价:技术可行性和临床应用(会议报告)

N. Huynh, A. Plumb, B. Cox, E. Zhang, P. Beard
{"title":"用于周围血管疾病评估的高分辨率三维光声扫描仪的临床评价:技术可行性和临床应用(会议报告)","authors":"N. Huynh, A. Plumb, B. Cox, E. Zhang, P. Beard","doi":"10.1117/12.2508498","DOIUrl":null,"url":null,"abstract":"Photoacoustic imaging instruments based on the Fabry Perot ultrasound sensing concept have been used extensively for the preclinical assessment of mouse models and shown to provide high fidelity images to sub-cm depths. In a new development, a 3D high resolution scanner based on the same technology has now been specifically engineered into a format comprising a mobile platform and a convenient hand-held imaging probe for clinical use. A number of key engineering developments designed to advance the clinical translation of the technology have been implemented. The system now employs a novel 32-channel optical scanning architecture and a 1kHz PRF excitation laser providing an order-of-magnitude faster acquisition than previous pre-clinical embodiments. 3D images can now be acquired within 1 second, and video rate 2D synthetic aperture imaging is achievable. Image acquisition speed can be further accelerated by employing sub-sampling techniques based on total variation and deep learning image reconstruction, e.g. 3D images can be obtained at the rate of 4Hz with a typical 25% sub-sampling factor. To further aid clinical utility, the scanner allows rapid switching between the two imaging modes. This enables the ROI to be searched for and located in real-time using the 2D video rate mode prior to 3D image acquisition. Additional recent technical developments include bias wavelength tracking for temperature compensation, synthetic 1.5D array based receive beam forming for out-of-plane signal rejection, fast image reconstruction and visualisation and the implementation of an intuitive user-friendly interface.\n\nTo confirm clinical applicability, proof-of-concept studies both in healthy volunteers and patients have been conducted using the system. Following ethical and local regulatory approval, consenting patients were recruited from a single tertiary care hospital. Participants had previously been diagnosed with peripheral vascular disease (PVD), head and neck malignant tumours (including nodal deposits), inflammatory arthritis, or were under active clinical investigation for these conditions. We obtained mutliwavelength 3D images of the superficial vasculature in critically-ischaemic and normally perfused regions in patients with PVD. In both cases, the photoacoustic images were compared to clinical B-mode and Doppler ultrasound scans. The results show that the scanner is able to visualise the spatial-temporal changes in human microvasculature and thus may be able to identify regions of ischaemia otherwise undetectable using existing modalities. Images of small joint arthopathies, and malignant lymph nodes were also obtained, and compared with contemporaneous high resolution ultrasound. Patients found the use of the scanner highly acceptable, both in degree of comfort and the duration of the scan procedure. This exploratory phase clinical study represents an initial step towards establishing the clinical utility of photoacoustic imaging in a range of clinical conditions.","PeriodicalId":206495,"journal":{"name":"Photons Plus Ultrasound: Imaging and Sensing 2019","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Clinical evaluation of a high resolution 3D photoacoustic scanner for the assessment of peripheral vascular disease: technical feasibility and clinical utility (Conference Presentation)\",\"authors\":\"N. Huynh, A. Plumb, B. Cox, E. Zhang, P. Beard\",\"doi\":\"10.1117/12.2508498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Photoacoustic imaging instruments based on the Fabry Perot ultrasound sensing concept have been used extensively for the preclinical assessment of mouse models and shown to provide high fidelity images to sub-cm depths. In a new development, a 3D high resolution scanner based on the same technology has now been specifically engineered into a format comprising a mobile platform and a convenient hand-held imaging probe for clinical use. A number of key engineering developments designed to advance the clinical translation of the technology have been implemented. The system now employs a novel 32-channel optical scanning architecture and a 1kHz PRF excitation laser providing an order-of-magnitude faster acquisition than previous pre-clinical embodiments. 3D images can now be acquired within 1 second, and video rate 2D synthetic aperture imaging is achievable. Image acquisition speed can be further accelerated by employing sub-sampling techniques based on total variation and deep learning image reconstruction, e.g. 3D images can be obtained at the rate of 4Hz with a typical 25% sub-sampling factor. To further aid clinical utility, the scanner allows rapid switching between the two imaging modes. This enables the ROI to be searched for and located in real-time using the 2D video rate mode prior to 3D image acquisition. Additional recent technical developments include bias wavelength tracking for temperature compensation, synthetic 1.5D array based receive beam forming for out-of-plane signal rejection, fast image reconstruction and visualisation and the implementation of an intuitive user-friendly interface.\\n\\nTo confirm clinical applicability, proof-of-concept studies both in healthy volunteers and patients have been conducted using the system. Following ethical and local regulatory approval, consenting patients were recruited from a single tertiary care hospital. Participants had previously been diagnosed with peripheral vascular disease (PVD), head and neck malignant tumours (including nodal deposits), inflammatory arthritis, or were under active clinical investigation for these conditions. We obtained mutliwavelength 3D images of the superficial vasculature in critically-ischaemic and normally perfused regions in patients with PVD. In both cases, the photoacoustic images were compared to clinical B-mode and Doppler ultrasound scans. The results show that the scanner is able to visualise the spatial-temporal changes in human microvasculature and thus may be able to identify regions of ischaemia otherwise undetectable using existing modalities. Images of small joint arthopathies, and malignant lymph nodes were also obtained, and compared with contemporaneous high resolution ultrasound. Patients found the use of the scanner highly acceptable, both in degree of comfort and the duration of the scan procedure. This exploratory phase clinical study represents an initial step towards establishing the clinical utility of photoacoustic imaging in a range of clinical conditions.\",\"PeriodicalId\":206495,\"journal\":{\"name\":\"Photons Plus Ultrasound: Imaging and Sensing 2019\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photons Plus Ultrasound: Imaging and Sensing 2019\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2508498\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photons Plus Ultrasound: Imaging and Sensing 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2508498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

基于Fabry Perot超声传感概念的光声成像仪器已广泛用于小鼠模型的临床前评估,并显示可提供亚厘米深度的高保真图像。在一项新的发展中,基于相同技术的3D高分辨率扫描仪现在已经被专门设计成一种格式,包括一个移动平台和一个方便的手持成像探针,用于临床使用。一些关键的工程发展,旨在推进临床翻译的技术已经实施。该系统现在采用了一种新颖的32通道光学扫描架构和1kHz PRF激励激光器,比以前的临床前实施例提供了更快的采集速度。现在可以在1秒内获得3D图像,并且可以实现视频速率的2D合成孔径成像。通过采用基于总变分和深度学习图像重建的子采样技术,可以进一步加快图像采集速度,例如,在典型的25%的子采样因子下,可以以4Hz的速率获得3D图像。为了进一步帮助临床应用,该扫描仪允许在两种成像模式之间快速切换。这使得在3D图像采集之前,可以使用2D视频速率模式实时搜索和定位ROI。最近的其他技术发展包括用于温度补偿的偏置波长跟踪,用于面外信号抑制的基于合成1.5D阵列的接收波束形成,快速图像重建和可视化以及直观的用户友好界面的实现。为了确认临床适用性,已经使用该系统在健康志愿者和患者中进行了概念验证研究。在伦理和当地监管部门批准后,从一家三级护理医院招募了同意的患者。参与者之前被诊断为周围血管疾病(PVD),头颈部恶性肿瘤(包括结节沉积),炎性关节炎,或正在积极进行这些疾病的临床调查。我们获得了PVD患者急性缺血和正常灌注区浅表血管的多波长3D图像。在这两种情况下,光声图像与临床b超和多普勒超声扫描进行比较。结果表明,扫描仪能够可视化人体微血管的时空变化,因此可能能够识别缺血区域,否则使用现有模式无法检测到。同时获得小关节病变和恶性淋巴结的图像,并与同期高分辨率超声进行比较。患者发现扫描仪的使用是高度可接受的,无论是在舒适程度和扫描过程的持续时间。这个探索性阶段的临床研究代表了在一系列临床条件下建立光声成像临床应用的第一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical evaluation of a high resolution 3D photoacoustic scanner for the assessment of peripheral vascular disease: technical feasibility and clinical utility (Conference Presentation)
Photoacoustic imaging instruments based on the Fabry Perot ultrasound sensing concept have been used extensively for the preclinical assessment of mouse models and shown to provide high fidelity images to sub-cm depths. In a new development, a 3D high resolution scanner based on the same technology has now been specifically engineered into a format comprising a mobile platform and a convenient hand-held imaging probe for clinical use. A number of key engineering developments designed to advance the clinical translation of the technology have been implemented. The system now employs a novel 32-channel optical scanning architecture and a 1kHz PRF excitation laser providing an order-of-magnitude faster acquisition than previous pre-clinical embodiments. 3D images can now be acquired within 1 second, and video rate 2D synthetic aperture imaging is achievable. Image acquisition speed can be further accelerated by employing sub-sampling techniques based on total variation and deep learning image reconstruction, e.g. 3D images can be obtained at the rate of 4Hz with a typical 25% sub-sampling factor. To further aid clinical utility, the scanner allows rapid switching between the two imaging modes. This enables the ROI to be searched for and located in real-time using the 2D video rate mode prior to 3D image acquisition. Additional recent technical developments include bias wavelength tracking for temperature compensation, synthetic 1.5D array based receive beam forming for out-of-plane signal rejection, fast image reconstruction and visualisation and the implementation of an intuitive user-friendly interface. To confirm clinical applicability, proof-of-concept studies both in healthy volunteers and patients have been conducted using the system. Following ethical and local regulatory approval, consenting patients were recruited from a single tertiary care hospital. Participants had previously been diagnosed with peripheral vascular disease (PVD), head and neck malignant tumours (including nodal deposits), inflammatory arthritis, or were under active clinical investigation for these conditions. We obtained mutliwavelength 3D images of the superficial vasculature in critically-ischaemic and normally perfused regions in patients with PVD. In both cases, the photoacoustic images were compared to clinical B-mode and Doppler ultrasound scans. The results show that the scanner is able to visualise the spatial-temporal changes in human microvasculature and thus may be able to identify regions of ischaemia otherwise undetectable using existing modalities. Images of small joint arthopathies, and malignant lymph nodes were also obtained, and compared with contemporaneous high resolution ultrasound. Patients found the use of the scanner highly acceptable, both in degree of comfort and the duration of the scan procedure. This exploratory phase clinical study represents an initial step towards establishing the clinical utility of photoacoustic imaging in a range of clinical conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信