Wilson Pavón, Esteban Inga, S. Simani, M. Armstrong
{"title":"一种新型单级双回路控制光伏系统直流/交流逆变器","authors":"Wilson Pavón, Esteban Inga, S. Simani, M. Armstrong","doi":"10.1109/SEGE55279.2022.9889762","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel double-loop control strategy for a single-stage boost inverter for a standalone photovoltaic system. This strategy includes compensation filters to avoid high currents and abrupt voltage variations. The final load has a non-linear behavior, representing new electronic components in the grid. The system is implemented in Matlab/Simulink platform, and the entire system is tested in situations like a temporary short circuit, non-linear loads, abrupt load variations, and input disturbance. The proposed control strategy allows the system a continuous operation, which means that the protection system is not triggered. Secondly, the total harmonic distortion (THD) percentage is a maximum of 1.845%, and the maximum voltage deviation compared with the reference error is 4%. Finally, the system efficiency average is more significant than 77% in the operation range.","PeriodicalId":338339,"journal":{"name":"2022 IEEE 10th International Conference on Smart Energy Grid Engineering (SEGE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel Single Stage DC/AC Power Inverter for a Standalone Photovoltaic System Controlled by a Double Loop Scheme\",\"authors\":\"Wilson Pavón, Esteban Inga, S. Simani, M. Armstrong\",\"doi\":\"10.1109/SEGE55279.2022.9889762\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel double-loop control strategy for a single-stage boost inverter for a standalone photovoltaic system. This strategy includes compensation filters to avoid high currents and abrupt voltage variations. The final load has a non-linear behavior, representing new electronic components in the grid. The system is implemented in Matlab/Simulink platform, and the entire system is tested in situations like a temporary short circuit, non-linear loads, abrupt load variations, and input disturbance. The proposed control strategy allows the system a continuous operation, which means that the protection system is not triggered. Secondly, the total harmonic distortion (THD) percentage is a maximum of 1.845%, and the maximum voltage deviation compared with the reference error is 4%. Finally, the system efficiency average is more significant than 77% in the operation range.\",\"PeriodicalId\":338339,\"journal\":{\"name\":\"2022 IEEE 10th International Conference on Smart Energy Grid Engineering (SEGE)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 10th International Conference on Smart Energy Grid Engineering (SEGE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SEGE55279.2022.9889762\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 10th International Conference on Smart Energy Grid Engineering (SEGE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SEGE55279.2022.9889762","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Novel Single Stage DC/AC Power Inverter for a Standalone Photovoltaic System Controlled by a Double Loop Scheme
This paper proposes a novel double-loop control strategy for a single-stage boost inverter for a standalone photovoltaic system. This strategy includes compensation filters to avoid high currents and abrupt voltage variations. The final load has a non-linear behavior, representing new electronic components in the grid. The system is implemented in Matlab/Simulink platform, and the entire system is tested in situations like a temporary short circuit, non-linear loads, abrupt load variations, and input disturbance. The proposed control strategy allows the system a continuous operation, which means that the protection system is not triggered. Secondly, the total harmonic distortion (THD) percentage is a maximum of 1.845%, and the maximum voltage deviation compared with the reference error is 4%. Finally, the system efficiency average is more significant than 77% in the operation range.