大功率中频变压器绕组设计

K. Iyer, W. Robbins, N. Mohan
{"title":"大功率中频变压器绕组设计","authors":"K. Iyer, W. Robbins, N. Mohan","doi":"10.1109/SPEEDAM.2014.6871956","DOIUrl":null,"url":null,"abstract":"The availability of improved magnetic materials and higher voltage rating semiconductor devices have made the design of high power medium frequency transformers feasible. The paper presents a simple design procedure to determine the core dimensions based on the area product method. A winding design procedure to use foil conductors in the high voltage side to achieve ac-to-dc resistance ratio close to 1 is also shown, providing a possible replacement to the litz wires having low window utilization factor. The paper demonstrates a design example of 13.8kV/690V, 10kHz, 50kVA transformer to validate the design methodology and the winding losses are validated using 2-D FEM.","PeriodicalId":344918,"journal":{"name":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Winding design of a high power medium frequency transformer\",\"authors\":\"K. Iyer, W. Robbins, N. Mohan\",\"doi\":\"10.1109/SPEEDAM.2014.6871956\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The availability of improved magnetic materials and higher voltage rating semiconductor devices have made the design of high power medium frequency transformers feasible. The paper presents a simple design procedure to determine the core dimensions based on the area product method. A winding design procedure to use foil conductors in the high voltage side to achieve ac-to-dc resistance ratio close to 1 is also shown, providing a possible replacement to the litz wires having low window utilization factor. The paper demonstrates a design example of 13.8kV/690V, 10kHz, 50kVA transformer to validate the design methodology and the winding losses are validated using 2-D FEM.\",\"PeriodicalId\":344918,\"journal\":{\"name\":\"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEEDAM.2014.6871956\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2014.6871956","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

改进的磁性材料和更高额定电压的半导体器件的可用性使大功率中频变压器的设计成为可能。本文提出了一种基于面积积法确定芯材尺寸的简单设计方法。还展示了在高压侧使用箔导体以实现交直流电阻比接近1的绕组设计程序,为具有低窗口利用系数的litz导线提供了可能的替代方案。以13.8kV/690V, 10kHz, 50kVA变压器为例,对设计方法进行了验证,并利用二维有限元法对绕组损耗进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Winding design of a high power medium frequency transformer
The availability of improved magnetic materials and higher voltage rating semiconductor devices have made the design of high power medium frequency transformers feasible. The paper presents a simple design procedure to determine the core dimensions based on the area product method. A winding design procedure to use foil conductors in the high voltage side to achieve ac-to-dc resistance ratio close to 1 is also shown, providing a possible replacement to the litz wires having low window utilization factor. The paper demonstrates a design example of 13.8kV/690V, 10kHz, 50kVA transformer to validate the design methodology and the winding losses are validated using 2-D FEM.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信