超宽带原位土壤介电常数探针与新的迭代校准方法

Ming Chen, Chi-Chih Chen
{"title":"超宽带原位土壤介电常数探针与新的迭代校准方法","authors":"Ming Chen, Chi-Chih Chen","doi":"10.1109/ICGPR.2012.6254841","DOIUrl":null,"url":null,"abstract":"A novel coaxial probe is developed for measuring complex permittivity of soils in-situ from 10 to 1000 MHz without taking soil samples. The dielectric constant and conductivity of soil is derived from step-frequency reflection taken inside a small freshly bored hole. As a result, permittivity at various depths with in-situ moisture content and soil texture can be obtained in the fields. A novel permittivity calibration method was developed to account for the frequency- and material-dependent geometrical factor which causes bias errors in conventional calibration methods. Simulated and experimental data are presented to prove the accuracy and efficiency of the proposed probe and calibration method.","PeriodicalId":443640,"journal":{"name":"2012 14th International Conference on Ground Penetrating Radar (GPR)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"UWB in-situ soil permittivity probe with a novel iterative permittivity calibration method\",\"authors\":\"Ming Chen, Chi-Chih Chen\",\"doi\":\"10.1109/ICGPR.2012.6254841\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel coaxial probe is developed for measuring complex permittivity of soils in-situ from 10 to 1000 MHz without taking soil samples. The dielectric constant and conductivity of soil is derived from step-frequency reflection taken inside a small freshly bored hole. As a result, permittivity at various depths with in-situ moisture content and soil texture can be obtained in the fields. A novel permittivity calibration method was developed to account for the frequency- and material-dependent geometrical factor which causes bias errors in conventional calibration methods. Simulated and experimental data are presented to prove the accuracy and efficiency of the proposed probe and calibration method.\",\"PeriodicalId\":443640,\"journal\":{\"name\":\"2012 14th International Conference on Ground Penetrating Radar (GPR)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 14th International Conference on Ground Penetrating Radar (GPR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICGPR.2012.6254841\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 14th International Conference on Ground Penetrating Radar (GPR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICGPR.2012.6254841","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

研制了一种新型同轴探针,可在10 ~ 1000 MHz范围内就地测量土壤的复介电常数。利用新钻小孔内的阶跃频率反射得到了土壤的介电常数和电导率。结果表明,不同深度的介电常数随土壤含水量和土壤质地的变化而变化。提出了一种新的介电常数校准方法,以解决传统校准方法中频率和材料相关的几何因素导致的偏置误差。仿真和实验数据证明了所提出的探针和校准方法的准确性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
UWB in-situ soil permittivity probe with a novel iterative permittivity calibration method
A novel coaxial probe is developed for measuring complex permittivity of soils in-situ from 10 to 1000 MHz without taking soil samples. The dielectric constant and conductivity of soil is derived from step-frequency reflection taken inside a small freshly bored hole. As a result, permittivity at various depths with in-situ moisture content and soil texture can be obtained in the fields. A novel permittivity calibration method was developed to account for the frequency- and material-dependent geometrical factor which causes bias errors in conventional calibration methods. Simulated and experimental data are presented to prove the accuracy and efficiency of the proposed probe and calibration method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信