羟基磷灰石和氟磷灰石包覆犬股骨髓内棒

M.T. Walenciak, M. Zimmerman, M. Deehan
{"title":"羟基磷灰石和氟磷灰石包覆犬股骨髓内棒","authors":"M.T. Walenciak, M. Zimmerman, M. Deehan","doi":"10.1109/NEBC.1993.404383","DOIUrl":null,"url":null,"abstract":"The effect of plasma sprayed synthetic calcium phosphate coatings, specifically hydroxylapatite (HA) and fluoroapatite (FA), on the degree of bone/implant attachment strength was investigated using a canine femoral intramedullary rod model. Titanium grit-blasted rods were implanted bilaterally, right side uncoated and the left side coated, in 12 coonhounds. The degree of bone attachment strength was determined by measuring the push-out force to failure and histological analysis after 3, 6, and 12 months implantation. For each time period there were four canines with either HA or FA coated implants. At 3 months, the HA and FA coatings promoted greater bone attachment strength (FA less so than HA) when compared to uncoated surfaces. At 6 months, all surfaces were statistically equivalent (with the FA, on average, exhibiting a lower strength). At 12 months, the HA and uncoated surfaces were equivalent, with the FA having a significantly lower strength.<<ETX>>","PeriodicalId":159783,"journal":{"name":"1993 IEEE Annual Northeast Bioengineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hydroxylapatite and fluoroapatite coated intramedullary rods in canine femurs\",\"authors\":\"M.T. Walenciak, M. Zimmerman, M. Deehan\",\"doi\":\"10.1109/NEBC.1993.404383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of plasma sprayed synthetic calcium phosphate coatings, specifically hydroxylapatite (HA) and fluoroapatite (FA), on the degree of bone/implant attachment strength was investigated using a canine femoral intramedullary rod model. Titanium grit-blasted rods were implanted bilaterally, right side uncoated and the left side coated, in 12 coonhounds. The degree of bone attachment strength was determined by measuring the push-out force to failure and histological analysis after 3, 6, and 12 months implantation. For each time period there were four canines with either HA or FA coated implants. At 3 months, the HA and FA coatings promoted greater bone attachment strength (FA less so than HA) when compared to uncoated surfaces. At 6 months, all surfaces were statistically equivalent (with the FA, on average, exhibiting a lower strength). At 12 months, the HA and uncoated surfaces were equivalent, with the FA having a significantly lower strength.<<ETX>>\",\"PeriodicalId\":159783,\"journal\":{\"name\":\"1993 IEEE Annual Northeast Bioengineering Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 IEEE Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1993.404383\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1993.404383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用犬股髓内棒模型研究了等离子喷涂合成磷酸钙涂层(特别是羟基磷灰石(HA)和氟磷灰石(FA))对骨/种植体附着强度的影响。12只猎犬双侧植入喷砂钛棒,右侧未涂覆,左侧未涂覆。通过测量植入后3、6、12个月的推出力和组织学分析来确定骨附着强度的程度。在每个时间段,有4只狗使用HA或FA涂层植入物。在3个月时,与未涂覆的表面相比,HA和FA涂层促进了更大的骨附着强度(FA不如HA)。在6个月时,所有表面在统计上是相等的(平均而言,FA表现出较低的强度)。12个月时,HA和未涂覆的表面强度相当,FA的强度明显较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hydroxylapatite and fluoroapatite coated intramedullary rods in canine femurs
The effect of plasma sprayed synthetic calcium phosphate coatings, specifically hydroxylapatite (HA) and fluoroapatite (FA), on the degree of bone/implant attachment strength was investigated using a canine femoral intramedullary rod model. Titanium grit-blasted rods were implanted bilaterally, right side uncoated and the left side coated, in 12 coonhounds. The degree of bone attachment strength was determined by measuring the push-out force to failure and histological analysis after 3, 6, and 12 months implantation. For each time period there were four canines with either HA or FA coated implants. At 3 months, the HA and FA coatings promoted greater bone attachment strength (FA less so than HA) when compared to uncoated surfaces. At 6 months, all surfaces were statistically equivalent (with the FA, on average, exhibiting a lower strength). At 12 months, the HA and uncoated surfaces were equivalent, with the FA having a significantly lower strength.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信