P. Martí, M. Velasco, Antonio Camacho, E. X. Martín, J. Fuertes
{"title":"基于事件驱动自触发方法的双积分器系统网络滑模控制","authors":"P. Martí, M. Velasco, Antonio Camacho, E. X. Martín, J. Fuertes","doi":"10.1109/ISIE.2011.5984472","DOIUrl":null,"url":null,"abstract":"Sliding mode control (SMC) methods rely on applying a high-frequency switching control. In networked control systems (NCS), high-frequency operations/transactions are not desirable because communication bandwidth consumption increases dramatically. This paper studies the application of event-driven self-triggered techniques to sliding mode control over networks as a means for reducing the bandwidth utilization. To this end, sliding mode control with hysteresis is adopted and control updates are forced to only occur at the hysteresis band boundary. This paper elaborates on the conditions that must be fulfilled in order to ensure such operation for the case of the double integrator system. Simulation results illustrate the presented concepts.","PeriodicalId":162453,"journal":{"name":"2011 IEEE International Symposium on Industrial Electronics","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Networked sliding mode control of the double integrator system using the event-driven self-triggered approach\",\"authors\":\"P. Martí, M. Velasco, Antonio Camacho, E. X. Martín, J. Fuertes\",\"doi\":\"10.1109/ISIE.2011.5984472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sliding mode control (SMC) methods rely on applying a high-frequency switching control. In networked control systems (NCS), high-frequency operations/transactions are not desirable because communication bandwidth consumption increases dramatically. This paper studies the application of event-driven self-triggered techniques to sliding mode control over networks as a means for reducing the bandwidth utilization. To this end, sliding mode control with hysteresis is adopted and control updates are forced to only occur at the hysteresis band boundary. This paper elaborates on the conditions that must be fulfilled in order to ensure such operation for the case of the double integrator system. Simulation results illustrate the presented concepts.\",\"PeriodicalId\":162453,\"journal\":{\"name\":\"2011 IEEE International Symposium on Industrial Electronics\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Symposium on Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2011.5984472\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2011.5984472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Networked sliding mode control of the double integrator system using the event-driven self-triggered approach
Sliding mode control (SMC) methods rely on applying a high-frequency switching control. In networked control systems (NCS), high-frequency operations/transactions are not desirable because communication bandwidth consumption increases dramatically. This paper studies the application of event-driven self-triggered techniques to sliding mode control over networks as a means for reducing the bandwidth utilization. To this end, sliding mode control with hysteresis is adopted and control updates are forced to only occur at the hysteresis band boundary. This paper elaborates on the conditions that must be fulfilled in order to ensure such operation for the case of the double integrator system. Simulation results illustrate the presented concepts.