{"title":"考虑最小能量损耗的光伏并网配电系统中储能系统的最佳选址和规模确定","authors":"Vattanak Sok, T. Tayjasanant","doi":"10.1109/ECTICON.2017.8096271","DOIUrl":null,"url":null,"abstract":"This paper proposes a technique using Energy Storage (ES) system to reduce power losses in distribution system where Photovoltaic (PV) is connected with grid, and mitigate voltage rise and voltage drop simultaneously. The sensitivity analysis of system loss is used to define the location of ES with the minimum energy losses. A modified IEEE 34-bus test system was simulated by Matlab/Simulink. Simulation results show that optimal siting and sizing of ES can help keeping voltages within the range and also minimizing energy losses.","PeriodicalId":273911,"journal":{"name":"2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Determination of optimal siting and sizing of energy storage system in PV-connected distribution systems considering minimum energy losses\",\"authors\":\"Vattanak Sok, T. Tayjasanant\",\"doi\":\"10.1109/ECTICON.2017.8096271\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a technique using Energy Storage (ES) system to reduce power losses in distribution system where Photovoltaic (PV) is connected with grid, and mitigate voltage rise and voltage drop simultaneously. The sensitivity analysis of system loss is used to define the location of ES with the minimum energy losses. A modified IEEE 34-bus test system was simulated by Matlab/Simulink. Simulation results show that optimal siting and sizing of ES can help keeping voltages within the range and also minimizing energy losses.\",\"PeriodicalId\":273911,\"journal\":{\"name\":\"2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTICON.2017.8096271\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2017.8096271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determination of optimal siting and sizing of energy storage system in PV-connected distribution systems considering minimum energy losses
This paper proposes a technique using Energy Storage (ES) system to reduce power losses in distribution system where Photovoltaic (PV) is connected with grid, and mitigate voltage rise and voltage drop simultaneously. The sensitivity analysis of system loss is used to define the location of ES with the minimum energy losses. A modified IEEE 34-bus test system was simulated by Matlab/Simulink. Simulation results show that optimal siting and sizing of ES can help keeping voltages within the range and also minimizing energy losses.