X. Bian, Liming Wang, Z. Guan, Jing Cao, Yingjian Yang, Xiong Wu
{"title":"基于移动电晕笼的输电线路直流正电晕起始电压高度修正系数实验研究","authors":"X. Bian, Liming Wang, Z. Guan, Jing Cao, Yingjian Yang, Xiong Wu","doi":"10.1109/ICHVE.2010.5640704","DOIUrl":null,"url":null,"abstract":"In order to obtain the altitude correction factor of corona inception voltage of HVDC transmission lines within the range 23 to 4000 meters, a mobile corona test cage was used to research the influence of altitude changes on positive DC corona characteristics of several kinds of conductors. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet detection apparatus. According to the apparent change of photon number, corona inception voltage could be acquired by the tangent method. With the obtained corona inception voltage in four altitudes, the exponential and linear correction formulas were introduced, which fitted well with the experimental values. Based on the correction relation, a correction coefficient of about −9.5%/1000m was recommended.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"370 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Experimental investigation on altitude correction factor of positive dc corona inception voltages of transmission lines based on the mobile corona cage\",\"authors\":\"X. Bian, Liming Wang, Z. Guan, Jing Cao, Yingjian Yang, Xiong Wu\",\"doi\":\"10.1109/ICHVE.2010.5640704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to obtain the altitude correction factor of corona inception voltage of HVDC transmission lines within the range 23 to 4000 meters, a mobile corona test cage was used to research the influence of altitude changes on positive DC corona characteristics of several kinds of conductors. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet detection apparatus. According to the apparent change of photon number, corona inception voltage could be acquired by the tangent method. With the obtained corona inception voltage in four altitudes, the exponential and linear correction formulas were introduced, which fitted well with the experimental values. Based on the correction relation, a correction coefficient of about −9.5%/1000m was recommended.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"370 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

为了获得23 ~ 4000米范围内高压直流输电线路电晕起始电压的海拔修正系数,采用移动电晕试验笼,研究了海拔变化对几种导体直流正电晕特性的影响。利用紫外检测仪对导体上电晕放电释放的光子进行了检测。根据光子数的明显变化,采用切线法获得电晕起始电压。根据得到的四个高度的电晕起始电压,给出了与实验值拟合较好的指数和线性修正公式。根据修正关系,建议修正系数约为- 9.5%/1000m。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental investigation on altitude correction factor of positive dc corona inception voltages of transmission lines based on the mobile corona cage
In order to obtain the altitude correction factor of corona inception voltage of HVDC transmission lines within the range 23 to 4000 meters, a mobile corona test cage was used to research the influence of altitude changes on positive DC corona characteristics of several kinds of conductors. Photons released as a result of corona discharge on the conductors were detected by the ultraviolet detection apparatus. According to the apparent change of photon number, corona inception voltage could be acquired by the tangent method. With the obtained corona inception voltage in four altitudes, the exponential and linear correction formulas were introduced, which fitted well with the experimental values. Based on the correction relation, a correction coefficient of about −9.5%/1000m was recommended.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信