电子回旋共振离子源光纤模拟信号链路

Nirupama Das, Indira Chatterjee, Anuraag Misra, Chirag Roy, S. Srivasatava
{"title":"电子回旋共振离子源光纤模拟信号链路","authors":"Nirupama Das, Indira Chatterjee, Anuraag Misra, Chirag Roy, S. Srivasatava","doi":"10.1109/IEMENTech48150.2019.8981060","DOIUrl":null,"url":null,"abstract":"Electron cyclotron resonance ion sources are very important systems to obtain highly energetic ions from the cyclotrons. The analog and digital signals should be sent to the control system for controlling and monitoring the operating parameters of the ion source. Due to the presence of harsh electromagnetic interference and high-voltages, a reliable analog fiber-optic signal link should be used in the ion source. According to the ECR ion source requirements, two analog fiberoptic signal links using voltage-to-frequency and frequency-to-voltage conversion circuits based on IC AD650 have been designed and developed. The test results indicate that the developed signal links for ECR ion sources are accurate and reliable.","PeriodicalId":243805,"journal":{"name":"2019 3rd International Conference on Electronics, Materials Engineering & Nano-Technology (IEMENTech)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fibre Optic Analog Signal Link for the Electron Cyclotron Resonance Ion Sources\",\"authors\":\"Nirupama Das, Indira Chatterjee, Anuraag Misra, Chirag Roy, S. Srivasatava\",\"doi\":\"10.1109/IEMENTech48150.2019.8981060\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electron cyclotron resonance ion sources are very important systems to obtain highly energetic ions from the cyclotrons. The analog and digital signals should be sent to the control system for controlling and monitoring the operating parameters of the ion source. Due to the presence of harsh electromagnetic interference and high-voltages, a reliable analog fiber-optic signal link should be used in the ion source. According to the ECR ion source requirements, two analog fiberoptic signal links using voltage-to-frequency and frequency-to-voltage conversion circuits based on IC AD650 have been designed and developed. The test results indicate that the developed signal links for ECR ion sources are accurate and reliable.\",\"PeriodicalId\":243805,\"journal\":{\"name\":\"2019 3rd International Conference on Electronics, Materials Engineering & Nano-Technology (IEMENTech)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 3rd International Conference on Electronics, Materials Engineering & Nano-Technology (IEMENTech)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMENTech48150.2019.8981060\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 3rd International Conference on Electronics, Materials Engineering & Nano-Technology (IEMENTech)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMENTech48150.2019.8981060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

电子回旋共振离子源是从回旋加速器中获得高能离子的重要系统。将模拟和数字信号发送到控制系统,用于控制和监测离子源的工作参数。由于存在恶劣的电磁干扰和高压,离子源应采用可靠的模拟光纤信号链路。根据ECR离子源的要求,设计并开发了基于集成电路AD650的电压-频率和频率-电压转换电路的两条模拟光纤信号链路。试验结果表明,所研制的ECR离子源信号链路准确可靠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fibre Optic Analog Signal Link for the Electron Cyclotron Resonance Ion Sources
Electron cyclotron resonance ion sources are very important systems to obtain highly energetic ions from the cyclotrons. The analog and digital signals should be sent to the control system for controlling and monitoring the operating parameters of the ion source. Due to the presence of harsh electromagnetic interference and high-voltages, a reliable analog fiber-optic signal link should be used in the ion source. According to the ECR ion source requirements, two analog fiberoptic signal links using voltage-to-frequency and frequency-to-voltage conversion circuits based on IC AD650 have been designed and developed. The test results indicate that the developed signal links for ECR ion sources are accurate and reliable.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信