R. Rinkevičienė, Z. Savickienė, Donatas Uznys, A. Pitrėnas, A. Šlepikas
{"title":"六相感应电动机的标量控制","authors":"R. Rinkevičienė, Z. Savickienė, Donatas Uznys, A. Pitrėnas, A. Šlepikas","doi":"10.1109/ESTREAM.2017.7950304","DOIUrl":null,"url":null,"abstract":"Paper presents MATLAB Simulink model of symmetrical six-phase motor controlled by six-phase frequency converter and analyses its dynamic performance in volts per hertz mode. The new control blocks were elaborated, because Simulink library has no blocks for six-phase motor control. The new reference frame transform blocks were designed for six-phase motor. The experimental stand to validate simulation results was designed and elaborated. Simulation results, compared with experiments indicated good adequacy of designed model.","PeriodicalId":174077,"journal":{"name":"2017 Open Conference of Electrical, Electronic and Information Sciences (eStream)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Scalar control of six-phase induction motor\",\"authors\":\"R. Rinkevičienė, Z. Savickienė, Donatas Uznys, A. Pitrėnas, A. Šlepikas\",\"doi\":\"10.1109/ESTREAM.2017.7950304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Paper presents MATLAB Simulink model of symmetrical six-phase motor controlled by six-phase frequency converter and analyses its dynamic performance in volts per hertz mode. The new control blocks were elaborated, because Simulink library has no blocks for six-phase motor control. The new reference frame transform blocks were designed for six-phase motor. The experimental stand to validate simulation results was designed and elaborated. Simulation results, compared with experiments indicated good adequacy of designed model.\",\"PeriodicalId\":174077,\"journal\":{\"name\":\"2017 Open Conference of Electrical, Electronic and Information Sciences (eStream)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Open Conference of Electrical, Electronic and Information Sciences (eStream)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESTREAM.2017.7950304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Open Conference of Electrical, Electronic and Information Sciences (eStream)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTREAM.2017.7950304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Paper presents MATLAB Simulink model of symmetrical six-phase motor controlled by six-phase frequency converter and analyses its dynamic performance in volts per hertz mode. The new control blocks were elaborated, because Simulink library has no blocks for six-phase motor control. The new reference frame transform blocks were designed for six-phase motor. The experimental stand to validate simulation results was designed and elaborated. Simulation results, compared with experiments indicated good adequacy of designed model.