{"title":"呼気試験法, ラジオアイソトープ法, アセトアミノフェン法による胃排出能検査の比較","authors":"大輔 白坂, 正明 加地, 伸郎 青山","doi":"10.1540/HEIKATSUKINZASHI1997.6.J107","DOIUrl":null,"url":null,"abstract":"The 13C-octanoic acid breath test has been thought to be one of the most important methods in gastric emptying, because it is non-invasive and needs no special device. In this study, we evaluated the gastric emptying results between the 13C-octanoic acid breath tests, scintigraphy, and acetaminophen method. Ten patients with non-ulcer dyspepsia and 4 healthy volunteers were studied. For the test meal, we used scrambled egg, white bread, and 150 ml water and into the scrambled egg, 100 mg of 13C-octanoic acid, 37 MBq 99mTc-DTPA, and 20 mg/kg body weight of acetaminophen were mixed. After eating, breath samples and scanning scintigraphic information was obtained up to 8 and 2 hours, respectively. Blood sample was obtained 45 minutes after eating and the concentration of serum acetaminophen were measured. Previously, a positive correlation between the half emptying time (t1/2) determined by breath test and scintigraphy, was reported by Ghoos et al.(1993) (y=1.12x+66.1, R2=0.79, p<0.0001) and in this study a positive correlation was found (y =0.76x +113, R2=0.29, p=0.047). There was a negative correlation between the t, 12 determined by scintigraphy and the concentration of serum acetaminophen (y=-0.12x+15.9, R2=0.40, p=0.013). In case of that 13CO2 excretion of breath test was remained, even 8 hours after eating, t1/2 and lag phase determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve in early phase was drawn like sigmoid curve, t1/2 determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve had two peak-points, there was no problem. In conclusion the 13C octanoic acid breath test is a promising and reliable method for measuring gastric emptying.","PeriodicalId":364748,"journal":{"name":"Journal of smooth muscle research. Japanese section","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of smooth muscle research. Japanese section","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1540/HEIKATSUKINZASHI1997.6.J107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

13c -辛酸呼气试验被认为是胃排空最重要的方法之一,因为它是非侵入性的,不需要特殊的设备。在这项研究中,我们评估了13c -辛酸呼气试验、闪烁成像和对乙酰氨基酚法之间的胃排空结果。研究了10例非溃疡性消化不良患者和4名健康志愿者。试验餐采用炒蛋、白面包和150ml水,在炒蛋中加入13c -辛酸100 mg、99mTc-DTPA 37 MBq、对乙酰氨基酚20 mg/kg体重混合。进食后,分别在8小时和2小时内获取呼吸样本和扫描图像信息。进食45分钟后采血,测定血清对乙酰氨基酚浓度。Ghoos et al.(1993)曾报道呼气试验测定的半排空时间(t1/2)与闪烁图呈正相关(y=1.12x+66.1, R2=0.79, p<0.0001),本研究发现两者呈正相关(y= 0.76x +113, R2=0.29, p=0.047)。闪烁显像测定的t, 12与血清对乙酰氨基酚浓度呈负相关(y=-0.12x+15.9, R2=0.40, p=0.013)。在呼吸试验中仍有13CO2排泄的情况下,即使进食后8小时,呼吸试验测定的t1/2和滞后期也比实际状态延迟。若以s型曲线绘制早期13CO2排泄曲线,则呼气试验测定的t1/2较实际状态延迟。如果13CO2排泄曲线有两个峰值,则没有问题。综上所述,13C辛酸呼气试验是一种有前途的、可靠的胃排空测定方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
呼気試験法, ラジオアイソトープ法, アセトアミノフェン法による胃排出能検査の比較
The 13C-octanoic acid breath test has been thought to be one of the most important methods in gastric emptying, because it is non-invasive and needs no special device. In this study, we evaluated the gastric emptying results between the 13C-octanoic acid breath tests, scintigraphy, and acetaminophen method. Ten patients with non-ulcer dyspepsia and 4 healthy volunteers were studied. For the test meal, we used scrambled egg, white bread, and 150 ml water and into the scrambled egg, 100 mg of 13C-octanoic acid, 37 MBq 99mTc-DTPA, and 20 mg/kg body weight of acetaminophen were mixed. After eating, breath samples and scanning scintigraphic information was obtained up to 8 and 2 hours, respectively. Blood sample was obtained 45 minutes after eating and the concentration of serum acetaminophen were measured. Previously, a positive correlation between the half emptying time (t1/2) determined by breath test and scintigraphy, was reported by Ghoos et al.(1993) (y=1.12x+66.1, R2=0.79, p<0.0001) and in this study a positive correlation was found (y =0.76x +113, R2=0.29, p=0.047). There was a negative correlation between the t, 12 determined by scintigraphy and the concentration of serum acetaminophen (y=-0.12x+15.9, R2=0.40, p=0.013). In case of that 13CO2 excretion of breath test was remained, even 8 hours after eating, t1/2 and lag phase determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve in early phase was drawn like sigmoid curve, t1/2 determined by breath test were more delayed than actual state. In case of that 13CO2 excretion curve had two peak-points, there was no problem. In conclusion the 13C octanoic acid breath test is a promising and reliable method for measuring gastric emptying.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信