用于401-406 MHz频段的MedRadio接收机链中的低噪声放大器的设计和测量技术

Abhishek Srivastava, Nithin Sankar, K. K. Rakesh, Baibhab Chatterjee, D. Das, M. Baghini
{"title":"用于401-406 MHz频段的MedRadio接收机链中的低噪声放大器的设计和测量技术","authors":"Abhishek Srivastava, Nithin Sankar, K. K. Rakesh, Baibhab Chatterjee, D. Das, M. Baghini","doi":"10.1109/ISVDAT.2016.8064846","DOIUrl":null,"url":null,"abstract":"This work presents design and practical techniques to measure specifications of a low noise amplifier (LNA) in a complete receiver chain at Medical Device Radio Communication (MedRadio) band in 401–406 MHz frequency range. Supported by detailed quantitative explanations, the proposed measurement methods help in characterizing the LNA without duplicating it on the chip only for the characterization and promises to save experimental time and cost. A common source inductively degenerated LNA has been designed and fabricated in 180 nm mixed mode CMOS technology. The measurement results show that the LNA consumes 700 μW power while giving a voltage gain of 31 dB, S11<-14 dB and noise figure of 5.8 dB at 400 MHz frequency. Complete receiver chain measurements with this LNA confirms the results from the proposed methods.","PeriodicalId":301815,"journal":{"name":"2016 20th International Symposium on VLSI Design and Test (VDAT)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and measurement techniques for a low noise amplifier in a receiver chain for MedRadio spectrum of 401–406 MHz frequency band\",\"authors\":\"Abhishek Srivastava, Nithin Sankar, K. K. Rakesh, Baibhab Chatterjee, D. Das, M. Baghini\",\"doi\":\"10.1109/ISVDAT.2016.8064846\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work presents design and practical techniques to measure specifications of a low noise amplifier (LNA) in a complete receiver chain at Medical Device Radio Communication (MedRadio) band in 401–406 MHz frequency range. Supported by detailed quantitative explanations, the proposed measurement methods help in characterizing the LNA without duplicating it on the chip only for the characterization and promises to save experimental time and cost. A common source inductively degenerated LNA has been designed and fabricated in 180 nm mixed mode CMOS technology. The measurement results show that the LNA consumes 700 μW power while giving a voltage gain of 31 dB, S11<-14 dB and noise figure of 5.8 dB at 400 MHz frequency. Complete receiver chain measurements with this LNA confirms the results from the proposed methods.\",\"PeriodicalId\":301815,\"journal\":{\"name\":\"2016 20th International Symposium on VLSI Design and Test (VDAT)\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 20th International Symposium on VLSI Design and Test (VDAT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISVDAT.2016.8064846\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 20th International Symposium on VLSI Design and Test (VDAT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISVDAT.2016.8064846","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本工作介绍了在401-406 MHz频率范围内医疗设备无线电通信(MedRadio)频段的完整接收器链中测量低噪声放大器(LNA)规格的设计和实用技术。在详细定量解释的支持下,所提出的测量方法有助于表征LNA,而无需在芯片上复制其仅用于表征,并有望节省实验时间和成本。采用180nm混合模式CMOS技术,设计并制作了一种共源电感退化LNA。测量结果表明,在400 MHz频率下,LNA功耗为700 μW,电压增益为31 dB, S11<-14 dB,噪声系数为5.8 dB。用这种LNA进行完整的接收机链测量,证实了所提出方法的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and measurement techniques for a low noise amplifier in a receiver chain for MedRadio spectrum of 401–406 MHz frequency band
This work presents design and practical techniques to measure specifications of a low noise amplifier (LNA) in a complete receiver chain at Medical Device Radio Communication (MedRadio) band in 401–406 MHz frequency range. Supported by detailed quantitative explanations, the proposed measurement methods help in characterizing the LNA without duplicating it on the chip only for the characterization and promises to save experimental time and cost. A common source inductively degenerated LNA has been designed and fabricated in 180 nm mixed mode CMOS technology. The measurement results show that the LNA consumes 700 μW power while giving a voltage gain of 31 dB, S11<-14 dB and noise figure of 5.8 dB at 400 MHz frequency. Complete receiver chain measurements with this LNA confirms the results from the proposed methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信