开关式触点机械参数对继电器动作特性的影响

W. Ren, Songjun Ma, G. Zhai, Huadong Xu
{"title":"开关式触点机械参数对继电器动作特性的影响","authors":"W. Ren, Songjun Ma, G. Zhai, Huadong Xu","doi":"10.1109/HOLM.2011.6034789","DOIUrl":null,"url":null,"abstract":"Electric arc erosion during contact break/make cause contact resistance degradation, material transfer, non-closing and non-opening, above failure modes affect relay operation characteristics greatly. A relay model testing device which could simulate relay parameters of: initial contact force between N.C. contacts, contact gap and N.O. over-travel mechanical parameters assembly was used to study arc erosion. During breaking and closing operation, contact resistance, pick-up/release voltage, pick-up/release/arc duration were recorded explicitly during test. The optimal matching mechanical parameters assembly of switch-type contact was determined by test results comprehensively. Therefore the contradiction between reducing arc duration and lower bouncing time was solved in maximum extent. The conclusions drawn in this paper are meaningful for optimization of mechanical parameters of switch-type contact in relay.","PeriodicalId":197233,"journal":{"name":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The effect of mechanical parameters of switch-type contact on relay operation characteristics\",\"authors\":\"W. Ren, Songjun Ma, G. Zhai, Huadong Xu\",\"doi\":\"10.1109/HOLM.2011.6034789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electric arc erosion during contact break/make cause contact resistance degradation, material transfer, non-closing and non-opening, above failure modes affect relay operation characteristics greatly. A relay model testing device which could simulate relay parameters of: initial contact force between N.C. contacts, contact gap and N.O. over-travel mechanical parameters assembly was used to study arc erosion. During breaking and closing operation, contact resistance, pick-up/release voltage, pick-up/release/arc duration were recorded explicitly during test. The optimal matching mechanical parameters assembly of switch-type contact was determined by test results comprehensively. Therefore the contradiction between reducing arc duration and lower bouncing time was solved in maximum extent. The conclusions drawn in this paper are meaningful for optimization of mechanical parameters of switch-type contact in relay.\",\"PeriodicalId\":197233,\"journal\":{\"name\":\"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2011.6034789\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2011.6034789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

触点断/合过程中的电弧侵蚀会导致触点电阻退化、物质转移、不合闸不开等故障,对继电器的工作特性影响很大。采用一种继电器模型试验装置,该装置可以模拟nnc触点初始接触力、触点间隙和nmo超行程机械参数组合等继电器参数,对电弧侵蚀进行了研究。在分断和合闸过程中,测试过程中明确记录了接触电阻、吸/释放电压、吸/释放/电弧持续时间。综合试验结果,确定了开关式触点的最优匹配力学参数组合。从而最大程度地解决了缩短电弧持续时间与缩短弹跳时间之间的矛盾。所得结论对继电器开关式触点的力学参数优化具有一定的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of mechanical parameters of switch-type contact on relay operation characteristics
Electric arc erosion during contact break/make cause contact resistance degradation, material transfer, non-closing and non-opening, above failure modes affect relay operation characteristics greatly. A relay model testing device which could simulate relay parameters of: initial contact force between N.C. contacts, contact gap and N.O. over-travel mechanical parameters assembly was used to study arc erosion. During breaking and closing operation, contact resistance, pick-up/release voltage, pick-up/release/arc duration were recorded explicitly during test. The optimal matching mechanical parameters assembly of switch-type contact was determined by test results comprehensively. Therefore the contradiction between reducing arc duration and lower bouncing time was solved in maximum extent. The conclusions drawn in this paper are meaningful for optimization of mechanical parameters of switch-type contact in relay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信