{"title":"高压10ns脉冲速率脉冲星的设计与研制","authors":"G. Kumar, A. Patel, Archana Sharma","doi":"10.1109/CATCON.2017.8280220","DOIUrl":null,"url":null,"abstract":"Rep-rate pulse generator has been developed for biomedical application, to trigger spark gap in high voltage applications etc, using avalanche mode operation of transistors and blumlein pulse forming line. The output voltage is up to 1.7kV, with rise time as fast as ∼4 nanoseconds and FWHM of 10 nanoseconds, having repetition rate of ∼4.5 kHz. We have developed this pulsar to observe the biological cell viability and morphological changes in biological cells at achieved voltage, pulse duration and frequency. System is working reliably with above parameter. Unit is discussed in detail.","PeriodicalId":250717,"journal":{"name":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design and development of high voltage 10ns rep-rate pulsar\",\"authors\":\"G. Kumar, A. Patel, Archana Sharma\",\"doi\":\"10.1109/CATCON.2017.8280220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Rep-rate pulse generator has been developed for biomedical application, to trigger spark gap in high voltage applications etc, using avalanche mode operation of transistors and blumlein pulse forming line. The output voltage is up to 1.7kV, with rise time as fast as ∼4 nanoseconds and FWHM of 10 nanoseconds, having repetition rate of ∼4.5 kHz. We have developed this pulsar to observe the biological cell viability and morphological changes in biological cells at achieved voltage, pulse duration and frequency. System is working reliably with above parameter. Unit is discussed in detail.\",\"PeriodicalId\":250717,\"journal\":{\"name\":\"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CATCON.2017.8280220\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON.2017.8280220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and development of high voltage 10ns rep-rate pulsar
Rep-rate pulse generator has been developed for biomedical application, to trigger spark gap in high voltage applications etc, using avalanche mode operation of transistors and blumlein pulse forming line. The output voltage is up to 1.7kV, with rise time as fast as ∼4 nanoseconds and FWHM of 10 nanoseconds, having repetition rate of ∼4.5 kHz. We have developed this pulsar to observe the biological cell viability and morphological changes in biological cells at achieved voltage, pulse duration and frequency. System is working reliably with above parameter. Unit is discussed in detail.