{"title":"补偿应用中短时电网电压均方根变化的快速检测","authors":"Houkai Zhang, G. Xiao, Zhaolin Lu","doi":"10.1109/ECCE-Asia49820.2021.9479387","DOIUrl":null,"url":null,"abstract":"To prevent sensitive loads from short-duration grid voltage root-mean-square (RMS) variation, the dynamic voltage restorer (DVR), a cost-effective solution widely used in practice, is required to compensate the load voltage as fast as possible; moreover, for many sensitive loads, the requirement on the full response time for the DVR has become even stricter nowadays. Thus, in this paper, a fast detection method for short-duration grid voltage RMS variation is proposed to accelerate the response of the DVR based on 4 approaches, achieving low time delay less than 1ms in most cases even for the grid voltage with distortions. Simulations and sufficient experiments verified the feasibility and the performance of the proposed method.","PeriodicalId":145366,"journal":{"name":"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)","volume":"29 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fast Detection of Short-Duration Grid Voltage RMS Variation for Compensation Applications\",\"authors\":\"Houkai Zhang, G. Xiao, Zhaolin Lu\",\"doi\":\"10.1109/ECCE-Asia49820.2021.9479387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To prevent sensitive loads from short-duration grid voltage root-mean-square (RMS) variation, the dynamic voltage restorer (DVR), a cost-effective solution widely used in practice, is required to compensate the load voltage as fast as possible; moreover, for many sensitive loads, the requirement on the full response time for the DVR has become even stricter nowadays. Thus, in this paper, a fast detection method for short-duration grid voltage RMS variation is proposed to accelerate the response of the DVR based on 4 approaches, achieving low time delay less than 1ms in most cases even for the grid voltage with distortions. Simulations and sufficient experiments verified the feasibility and the performance of the proposed method.\",\"PeriodicalId\":145366,\"journal\":{\"name\":\"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)\",\"volume\":\"29 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE-Asia49820.2021.9479387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE-Asia49820.2021.9479387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fast Detection of Short-Duration Grid Voltage RMS Variation for Compensation Applications
To prevent sensitive loads from short-duration grid voltage root-mean-square (RMS) variation, the dynamic voltage restorer (DVR), a cost-effective solution widely used in practice, is required to compensate the load voltage as fast as possible; moreover, for many sensitive loads, the requirement on the full response time for the DVR has become even stricter nowadays. Thus, in this paper, a fast detection method for short-duration grid voltage RMS variation is proposed to accelerate the response of the DVR based on 4 approaches, achieving low time delay less than 1ms in most cases even for the grid voltage with distortions. Simulations and sufficient experiments verified the feasibility and the performance of the proposed method.