补偿应用中短时电网电压均方根变化的快速检测

Houkai Zhang, G. Xiao, Zhaolin Lu
{"title":"补偿应用中短时电网电压均方根变化的快速检测","authors":"Houkai Zhang, G. Xiao, Zhaolin Lu","doi":"10.1109/ECCE-Asia49820.2021.9479387","DOIUrl":null,"url":null,"abstract":"To prevent sensitive loads from short-duration grid voltage root-mean-square (RMS) variation, the dynamic voltage restorer (DVR), a cost-effective solution widely used in practice, is required to compensate the load voltage as fast as possible; moreover, for many sensitive loads, the requirement on the full response time for the DVR has become even stricter nowadays. Thus, in this paper, a fast detection method for short-duration grid voltage RMS variation is proposed to accelerate the response of the DVR based on 4 approaches, achieving low time delay less than 1ms in most cases even for the grid voltage with distortions. Simulations and sufficient experiments verified the feasibility and the performance of the proposed method.","PeriodicalId":145366,"journal":{"name":"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)","volume":"29 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fast Detection of Short-Duration Grid Voltage RMS Variation for Compensation Applications\",\"authors\":\"Houkai Zhang, G. Xiao, Zhaolin Lu\",\"doi\":\"10.1109/ECCE-Asia49820.2021.9479387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To prevent sensitive loads from short-duration grid voltage root-mean-square (RMS) variation, the dynamic voltage restorer (DVR), a cost-effective solution widely used in practice, is required to compensate the load voltage as fast as possible; moreover, for many sensitive loads, the requirement on the full response time for the DVR has become even stricter nowadays. Thus, in this paper, a fast detection method for short-duration grid voltage RMS variation is proposed to accelerate the response of the DVR based on 4 approaches, achieving low time delay less than 1ms in most cases even for the grid voltage with distortions. Simulations and sufficient experiments verified the feasibility and the performance of the proposed method.\",\"PeriodicalId\":145366,\"journal\":{\"name\":\"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)\",\"volume\":\"29 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE-Asia49820.2021.9479387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE-Asia49820.2021.9479387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了防止电网电压均方根(RMS)短时变化对敏感负荷的影响,需要动态电压恢复器(DVR)对负荷电压进行快速补偿,这是一种广泛应用于实际的经济有效的解决方案;此外,对于许多敏感负载,对DVR的全响应时间要求越来越高。因此,本文在4种方法的基础上,提出了一种短时电网电压均方根变化的快速检测方法,加快了DVR的响应速度,即使对有畸变的电网电压,也能在大多数情况下实现小于1ms的低时延。仿真和充分的实验验证了该方法的可行性和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fast Detection of Short-Duration Grid Voltage RMS Variation for Compensation Applications
To prevent sensitive loads from short-duration grid voltage root-mean-square (RMS) variation, the dynamic voltage restorer (DVR), a cost-effective solution widely used in practice, is required to compensate the load voltage as fast as possible; moreover, for many sensitive loads, the requirement on the full response time for the DVR has become even stricter nowadays. Thus, in this paper, a fast detection method for short-duration grid voltage RMS variation is proposed to accelerate the response of the DVR based on 4 approaches, achieving low time delay less than 1ms in most cases even for the grid voltage with distortions. Simulations and sufficient experiments verified the feasibility and the performance of the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信