基于复变滤波的PV集成DSTATCOM性能评价

B. K. Verma, Sachin Devassy, Subhash Kumar Ram, A. Abhishek, A. Dhakar
{"title":"基于复变滤波的PV集成DSTATCOM性能评价","authors":"B. K. Verma, Sachin Devassy, Subhash Kumar Ram, A. Abhishek, A. Dhakar","doi":"10.1109/ICEES.2018.8442402","DOIUrl":null,"url":null,"abstract":"Extraction of fundamental active component of load current is the key for any distribution static compensator (DSTATCOM). In this study, a control technique based upon complex variable filter and second order generalized integrator (SOGI) has been used for single phase photovoltaic integrated distribution static compensator (PV-DSTATCOM). Active component of load current is extracted with the help of a filter and it is used to control the pulses of DSTATCOM. A two stage system consisting of a full bridge boost converter in cascade with an inverter is taken to model a DSTATCOM. Power is drawn maximally from the PV panel. Dynamic conditions like step load change and linear irradiation change have been employed to study the performance of the system for this control strategy.","PeriodicalId":134828,"journal":{"name":"2018 4th International Conference on Electrical Energy Systems (ICEES)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Performance Evaluation of PV Integrated DSTATCOM Based on Complex Variable Filter\",\"authors\":\"B. K. Verma, Sachin Devassy, Subhash Kumar Ram, A. Abhishek, A. Dhakar\",\"doi\":\"10.1109/ICEES.2018.8442402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Extraction of fundamental active component of load current is the key for any distribution static compensator (DSTATCOM). In this study, a control technique based upon complex variable filter and second order generalized integrator (SOGI) has been used for single phase photovoltaic integrated distribution static compensator (PV-DSTATCOM). Active component of load current is extracted with the help of a filter and it is used to control the pulses of DSTATCOM. A two stage system consisting of a full bridge boost converter in cascade with an inverter is taken to model a DSTATCOM. Power is drawn maximally from the PV panel. Dynamic conditions like step load change and linear irradiation change have been employed to study the performance of the system for this control strategy.\",\"PeriodicalId\":134828,\"journal\":{\"name\":\"2018 4th International Conference on Electrical Energy Systems (ICEES)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 4th International Conference on Electrical Energy Systems (ICEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEES.2018.8442402\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 4th International Conference on Electrical Energy Systems (ICEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEES.2018.8442402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

负载电流基态有功分量的提取是分布式静态补偿器的关键。本文将复杂变量滤波与二阶广义积分器(SOGI)相结合的控制技术应用于单相光伏综合分配静态补偿器(PV-DSTATCOM)。利用滤波器提取负载电流的有源分量,用于控制DSTATCOM的脉冲。采用全桥升压变换器与逆变器级联组成的两级系统对DSTATCOM进行建模。最大限度地从光伏板中获取电力。采用负荷阶跃变化和辐照线性变化等动态条件对该控制策略进行了系统性能研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Evaluation of PV Integrated DSTATCOM Based on Complex Variable Filter
Extraction of fundamental active component of load current is the key for any distribution static compensator (DSTATCOM). In this study, a control technique based upon complex variable filter and second order generalized integrator (SOGI) has been used for single phase photovoltaic integrated distribution static compensator (PV-DSTATCOM). Active component of load current is extracted with the help of a filter and it is used to control the pulses of DSTATCOM. A two stage system consisting of a full bridge boost converter in cascade with an inverter is taken to model a DSTATCOM. Power is drawn maximally from the PV panel. Dynamic conditions like step load change and linear irradiation change have been employed to study the performance of the system for this control strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信