基于合成孔径的超宽带成像系统用于检测膀胱内尿液积聚

Xuyang Li, M. Jalilvand, L. Zwirello, T. Zwick
{"title":"基于合成孔径的超宽带成像系统用于检测膀胱内尿液积聚","authors":"Xuyang Li, M. Jalilvand, L. Zwirello, T. Zwick","doi":"10.1109/ICUWB.2011.6058862","DOIUrl":null,"url":null,"abstract":"This paper presents a synthetic aperture-based UWB radar imaging system. The goal is to detect the urine accumulation in the human bladder. To verify this radar concept a bladder model with various human tissues including realistic dielectric properties is simulated. Two scan configurations with different antenna positions are used to investigate the influence of the synthetic aperture length and position number in the microwave images. To generate the imaging results, Delay and Sum algorithm together with coherent weighting is applied. The achieved imaging results demonstrate the possibility of detecting the position and volume of urine in the human bladder and therefore the potential application of this radar imaging system in the clinics for diagnosis purposes.","PeriodicalId":143107,"journal":{"name":"2011 IEEE International Conference on Ultra-Wideband (ICUWB)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Synthetic aperture-based UWB imaging system for detection of urine accumulation in human bladder\",\"authors\":\"Xuyang Li, M. Jalilvand, L. Zwirello, T. Zwick\",\"doi\":\"10.1109/ICUWB.2011.6058862\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a synthetic aperture-based UWB radar imaging system. The goal is to detect the urine accumulation in the human bladder. To verify this radar concept a bladder model with various human tissues including realistic dielectric properties is simulated. Two scan configurations with different antenna positions are used to investigate the influence of the synthetic aperture length and position number in the microwave images. To generate the imaging results, Delay and Sum algorithm together with coherent weighting is applied. The achieved imaging results demonstrate the possibility of detecting the position and volume of urine in the human bladder and therefore the potential application of this radar imaging system in the clinics for diagnosis purposes.\",\"PeriodicalId\":143107,\"journal\":{\"name\":\"2011 IEEE International Conference on Ultra-Wideband (ICUWB)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Conference on Ultra-Wideband (ICUWB)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICUWB.2011.6058862\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Ultra-Wideband (ICUWB)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICUWB.2011.6058862","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

提出了一种基于合成孔径的超宽带雷达成像系统。目的是检测尿液在人类膀胱中的积聚情况。为了验证这一雷达概念,模拟了具有各种人体组织的膀胱模型,包括真实的介电特性。采用两种不同天线位置的扫描配置,研究了合成孔径长度和位置数对微波图像的影响。为了生成成像结果,采用了延迟和和算法,并结合相干加权。所取得的成像结果证明了检测尿液在人体膀胱中的位置和体积的可能性,因此该雷达成像系统在临床诊断中的潜在应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Synthetic aperture-based UWB imaging system for detection of urine accumulation in human bladder
This paper presents a synthetic aperture-based UWB radar imaging system. The goal is to detect the urine accumulation in the human bladder. To verify this radar concept a bladder model with various human tissues including realistic dielectric properties is simulated. Two scan configurations with different antenna positions are used to investigate the influence of the synthetic aperture length and position number in the microwave images. To generate the imaging results, Delay and Sum algorithm together with coherent weighting is applied. The achieved imaging results demonstrate the possibility of detecting the position and volume of urine in the human bladder and therefore the potential application of this radar imaging system in the clinics for diagnosis purposes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信