W. Bula, Y. Takahata, K. Aritome, Y. Murakami, J. Gardeniers, R. Miyake
{"title":"混合技术(3D增材打印-硅玻璃)多线蒸发浓缩器用于水质监测系统","authors":"W. Bula, Y. Takahata, K. Aritome, Y. Murakami, J. Gardeniers, R. Miyake","doi":"10.1109/TRANSDUCERS.2013.6626787","DOIUrl":null,"url":null,"abstract":"This paper reports the design, fabrication procedure and functional tests of a continuous-flow hybrid technology 16-line evaporative concentrator. The unique and complete integration of the microscale silicon-glass evaporator with a mesoscale 3D printed polymer manifold platform is successfully demonstrated. The hardware platform of concentrator control unit is described. The continuous-flow concentrator chips were tested with respect to their evaporation capability. A very high water evaporation rates were achieved in evaporative concentrator. An evaporation rate of 10 μL/min, achieved in mild conditions, compatible with biological sample treatment (T≤37°C), allowed for 4-fold sample enrichment. High-throughput flow ability and 33-fold concentration factor achieved in temperature of 50°C facilitates the application of prototype for chemical sample enrichment.","PeriodicalId":202479,"journal":{"name":"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hybrid technology (3D additive printing — silicon — glass) multiline evaporative concentrator for water quality monitoring system\",\"authors\":\"W. Bula, Y. Takahata, K. Aritome, Y. Murakami, J. Gardeniers, R. Miyake\",\"doi\":\"10.1109/TRANSDUCERS.2013.6626787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports the design, fabrication procedure and functional tests of a continuous-flow hybrid technology 16-line evaporative concentrator. The unique and complete integration of the microscale silicon-glass evaporator with a mesoscale 3D printed polymer manifold platform is successfully demonstrated. The hardware platform of concentrator control unit is described. The continuous-flow concentrator chips were tested with respect to their evaporation capability. A very high water evaporation rates were achieved in evaporative concentrator. An evaporation rate of 10 μL/min, achieved in mild conditions, compatible with biological sample treatment (T≤37°C), allowed for 4-fold sample enrichment. High-throughput flow ability and 33-fold concentration factor achieved in temperature of 50°C facilitates the application of prototype for chemical sample enrichment.\",\"PeriodicalId\":202479,\"journal\":{\"name\":\"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRANSDUCERS.2013.6626787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2013.6626787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Hybrid technology (3D additive printing — silicon — glass) multiline evaporative concentrator for water quality monitoring system
This paper reports the design, fabrication procedure and functional tests of a continuous-flow hybrid technology 16-line evaporative concentrator. The unique and complete integration of the microscale silicon-glass evaporator with a mesoscale 3D printed polymer manifold platform is successfully demonstrated. The hardware platform of concentrator control unit is described. The continuous-flow concentrator chips were tested with respect to their evaporation capability. A very high water evaporation rates were achieved in evaporative concentrator. An evaporation rate of 10 μL/min, achieved in mild conditions, compatible with biological sample treatment (T≤37°C), allowed for 4-fold sample enrichment. High-throughput flow ability and 33-fold concentration factor achieved in temperature of 50°C facilitates the application of prototype for chemical sample enrichment.