职业接触四氢呋喃的生物监测。

C N Ong, S E Chia, W H Phoon, K T Tan
{"title":"职业接触四氢呋喃的生物监测。","authors":"C N Ong,&nbsp;S E Chia,&nbsp;W H Phoon,&nbsp;K T Tan","doi":"10.1136/oem.48.9.616","DOIUrl":null,"url":null,"abstract":"<p><p>Occupational exposure to tetrahydrofuran (THF) was studied by analysis of environmental air, blood, alveolar air, and urine from 58 workers in a video tape manufacturing plant. Head space gas chromatography (GC) with an FID detector was used for determination of THF concentration in alveolar air, urine, and blood. Environmental exposure to THF was measured by personal sampling with a carbon felt passive dosimeter. When the end of shift urinary THF concentrations were compared with environmental time weighted average (TWA) values, urinary THF concentration corrected for specific gravity correlated well with THF concentration in air (r = 0.88), and uncorrected urinary THF concentration gave a similar result (r = 0.86). Correction for creatinine in urine weakened the correlation (r = 0.56). For exposure at the TWA concentration of 200 ppm the extrapolated concentration of THF was 33 mumol/l in blood and 111.9 mumol/l (61 mumol/g creatinine) or 109 mumol/l at a specific gravity of 1.018 in urine. The correlation between exposure to THF and its concentration in exhaled breath and blood was low (r = 0.61 and 0.68 respectively). Laboratory methodological considerations together with the good correlation between urinary THF concentration and the environmental concentration suggest that THF concentration in urine is a useful biological indicator of occupational exposure to THF.</p>","PeriodicalId":9254,"journal":{"name":"British Journal of Industrial Medicine","volume":"48 9","pages":"616-21"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1136/oem.48.9.616","citationCount":"25","resultStr":"{\"title\":\"Biological monitoring of occupational exposure to tetrahydrofuran.\",\"authors\":\"C N Ong,&nbsp;S E Chia,&nbsp;W H Phoon,&nbsp;K T Tan\",\"doi\":\"10.1136/oem.48.9.616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Occupational exposure to tetrahydrofuran (THF) was studied by analysis of environmental air, blood, alveolar air, and urine from 58 workers in a video tape manufacturing plant. Head space gas chromatography (GC) with an FID detector was used for determination of THF concentration in alveolar air, urine, and blood. Environmental exposure to THF was measured by personal sampling with a carbon felt passive dosimeter. When the end of shift urinary THF concentrations were compared with environmental time weighted average (TWA) values, urinary THF concentration corrected for specific gravity correlated well with THF concentration in air (r = 0.88), and uncorrected urinary THF concentration gave a similar result (r = 0.86). Correction for creatinine in urine weakened the correlation (r = 0.56). For exposure at the TWA concentration of 200 ppm the extrapolated concentration of THF was 33 mumol/l in blood and 111.9 mumol/l (61 mumol/g creatinine) or 109 mumol/l at a specific gravity of 1.018 in urine. The correlation between exposure to THF and its concentration in exhaled breath and blood was low (r = 0.61 and 0.68 respectively). Laboratory methodological considerations together with the good correlation between urinary THF concentration and the environmental concentration suggest that THF concentration in urine is a useful biological indicator of occupational exposure to THF.</p>\",\"PeriodicalId\":9254,\"journal\":{\"name\":\"British Journal of Industrial Medicine\",\"volume\":\"48 9\",\"pages\":\"616-21\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1136/oem.48.9.616\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British Journal of Industrial Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1136/oem.48.9.616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Industrial Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/oem.48.9.616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

通过对某录像带制造厂58名工人的环境空气、血液、肺泡空气和尿液的分析,研究了四氢呋喃(THF)的职业性暴露。采用气相色谱法(GC)和FID检测器分别测定肺泡空气、尿液和血液中的四氢呋喃(THF)浓度。环境暴露于THF是由个人取样与碳毡被动剂量计测量。当换班结束时尿THF浓度与环境时间加权平均值(TWA)值进行比较时,经比重校正的尿THF浓度与空气中THF浓度相关性良好(r = 0.88),未校正的尿THF浓度也得到类似结果(r = 0.86)。校正尿肌酐降低了相关性(r = 0.56)。在TWA浓度为200ppm时,血液中THF的外推浓度为33 μ mol/l,尿液中THF的浓度为111.9 μ mol/l (61 μ mol/g肌酐)或109 μ mol/l(比重为1.018)。四氢呋喃暴露与呼出气体和血液中四氢呋喃浓度的相关性较低(r分别为0.61和0.68)。实验室方法学考虑以及尿中四氢呋喃浓度与环境浓度之间的良好相关性表明,尿中四氢呋喃浓度是职业四氢呋喃暴露的有用生物学指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biological monitoring of occupational exposure to tetrahydrofuran.

Occupational exposure to tetrahydrofuran (THF) was studied by analysis of environmental air, blood, alveolar air, and urine from 58 workers in a video tape manufacturing plant. Head space gas chromatography (GC) with an FID detector was used for determination of THF concentration in alveolar air, urine, and blood. Environmental exposure to THF was measured by personal sampling with a carbon felt passive dosimeter. When the end of shift urinary THF concentrations were compared with environmental time weighted average (TWA) values, urinary THF concentration corrected for specific gravity correlated well with THF concentration in air (r = 0.88), and uncorrected urinary THF concentration gave a similar result (r = 0.86). Correction for creatinine in urine weakened the correlation (r = 0.56). For exposure at the TWA concentration of 200 ppm the extrapolated concentration of THF was 33 mumol/l in blood and 111.9 mumol/l (61 mumol/g creatinine) or 109 mumol/l at a specific gravity of 1.018 in urine. The correlation between exposure to THF and its concentration in exhaled breath and blood was low (r = 0.61 and 0.68 respectively). Laboratory methodological considerations together with the good correlation between urinary THF concentration and the environmental concentration suggest that THF concentration in urine is a useful biological indicator of occupational exposure to THF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信