{"title":"利用flstatcom提高暂态稳定性","authors":"P. Pandit, Rohit Kumar, Manju M. Gupta","doi":"10.30780/IJTRS.V05.I12.003","DOIUrl":null,"url":null,"abstract":"Power system stability is one of the most crucial issues which deals with the response of the system to the errors such as: Sudden load change, Short circuit, Prime mover failure, Excitation failure etc. To maintain the stability and the damping oscillation of power system. Recently, FACTS controllers have been proposed to enhance the transient or dynamic stability of the power systems, e.g.: SVC, TCSC, STATCOM. In this a fuzzy logic controller is proposed to apply a suitable control signal to STATCOM. To improve the fault clearing time and transient stability improvement within a particular duration. It is found that the fault clearing times of 0.10sec for generator (G1) under test are self-stable with respect to simulation time. Proposed method is implemented in a single machine infinite bus system and the results are compared with conventional energy function-based controllers.","PeriodicalId":302312,"journal":{"name":"International Journal of Technical Research & Science","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"IMPROVEMENT OF TRANSIENT STABILITY BY USING FLSTATCOM\",\"authors\":\"P. Pandit, Rohit Kumar, Manju M. Gupta\",\"doi\":\"10.30780/IJTRS.V05.I12.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power system stability is one of the most crucial issues which deals with the response of the system to the errors such as: Sudden load change, Short circuit, Prime mover failure, Excitation failure etc. To maintain the stability and the damping oscillation of power system. Recently, FACTS controllers have been proposed to enhance the transient or dynamic stability of the power systems, e.g.: SVC, TCSC, STATCOM. In this a fuzzy logic controller is proposed to apply a suitable control signal to STATCOM. To improve the fault clearing time and transient stability improvement within a particular duration. It is found that the fault clearing times of 0.10sec for generator (G1) under test are self-stable with respect to simulation time. Proposed method is implemented in a single machine infinite bus system and the results are compared with conventional energy function-based controllers.\",\"PeriodicalId\":302312,\"journal\":{\"name\":\"International Journal of Technical Research & Science\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Technical Research & Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30780/IJTRS.V05.I12.003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Technical Research & Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30780/IJTRS.V05.I12.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电力系统的稳定性是解决系统对负荷突然变化、短路、原动机故障、励磁故障等故障响应的关键问题之一。维持电力系统的稳定性和阻尼振荡。近年来,人们提出了FACTS控制器来提高电力系统的暂态或动态稳定性,例如:SVC、TCSC、STATCOM。在此基础上,提出了一种模糊控制器,对STATCOM施加合适的控制信号。提高故障清除时间,提高特定时间段内的暂态稳定性。结果表明,被测发电机(G1)在0.1秒的故障清除时间相对于仿真时间是自稳定的。在单机无限总线系统中实现了该方法,并与传统的能量函数控制器进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
IMPROVEMENT OF TRANSIENT STABILITY BY USING FLSTATCOM
Power system stability is one of the most crucial issues which deals with the response of the system to the errors such as: Sudden load change, Short circuit, Prime mover failure, Excitation failure etc. To maintain the stability and the damping oscillation of power system. Recently, FACTS controllers have been proposed to enhance the transient or dynamic stability of the power systems, e.g.: SVC, TCSC, STATCOM. In this a fuzzy logic controller is proposed to apply a suitable control signal to STATCOM. To improve the fault clearing time and transient stability improvement within a particular duration. It is found that the fault clearing times of 0.10sec for generator (G1) under test are self-stable with respect to simulation time. Proposed method is implemented in a single machine infinite bus system and the results are compared with conventional energy function-based controllers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信