电网对抽水蓄能电站稳定性的影响

S. Mansoor
{"title":"电网对抽水蓄能电站稳定性的影响","authors":"S. Mansoor","doi":"10.1109/ICMIC.2014.7020723","DOIUrl":null,"url":null,"abstract":"The ability of pump storage hydropower stations to provide a rapid response to changes in system loading means that they are often used as a measure of controlling Grid frequency. When used in this role, the response of an individual unit is determined by the behaviour of its governor, the stiffness of the connected grid and the interaction between the governor and the grid. The governor settings, and in particular the loop gains, are therefore critical to achieving optimum levels of station performance. However, the level of interaction between the governor and the grid means that in order to achieve optimum performance the governor loop gains should be continually modified to take account of grid loading.","PeriodicalId":405363,"journal":{"name":"Proceedings of 2014 International Conference on Modelling, Identification & Control","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Grid effect on stability of pumped-storage hydro station\",\"authors\":\"S. Mansoor\",\"doi\":\"10.1109/ICMIC.2014.7020723\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ability of pump storage hydropower stations to provide a rapid response to changes in system loading means that they are often used as a measure of controlling Grid frequency. When used in this role, the response of an individual unit is determined by the behaviour of its governor, the stiffness of the connected grid and the interaction between the governor and the grid. The governor settings, and in particular the loop gains, are therefore critical to achieving optimum levels of station performance. However, the level of interaction between the governor and the grid means that in order to achieve optimum performance the governor loop gains should be continually modified to take account of grid loading.\",\"PeriodicalId\":405363,\"journal\":{\"name\":\"Proceedings of 2014 International Conference on Modelling, Identification & Control\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 2014 International Conference on Modelling, Identification & Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMIC.2014.7020723\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2014 International Conference on Modelling, Identification & Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMIC.2014.7020723","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

抽水蓄能水电站对系统负荷变化的快速响应能力意味着它们经常被用作控制电网频率的措施。当在此角色中使用时,单个单元的响应由其调节器的行为,连接网格的刚度以及调节器与网格之间的相互作用决定。因此,调速器设置,特别是环路增益,对于达到最佳的站性能水平至关重要。然而,调控器和网格之间的交互级别意味着,为了获得最佳性能,应该不断修改调控器环路增益,以考虑网格负载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Grid effect on stability of pumped-storage hydro station
The ability of pump storage hydropower stations to provide a rapid response to changes in system loading means that they are often used as a measure of controlling Grid frequency. When used in this role, the response of an individual unit is determined by the behaviour of its governor, the stiffness of the connected grid and the interaction between the governor and the grid. The governor settings, and in particular the loop gains, are therefore critical to achieving optimum levels of station performance. However, the level of interaction between the governor and the grid means that in order to achieve optimum performance the governor loop gains should be continually modified to take account of grid loading.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信