从总漏电流中提取表面电流的11kV瓷针绝缘子状态监测

Suhas Deb, R. Ghosh, S. Dutta, S. Dalai, B. Chatterjee
{"title":"从总漏电流中提取表面电流的11kV瓷针绝缘子状态监测","authors":"Suhas Deb, R. Ghosh, S. Dutta, S. Dalai, B. Chatterjee","doi":"10.1109/CATCON.2017.8280253","DOIUrl":null,"url":null,"abstract":"Insulators are one of the most important components of the power system. Outdoor insulators get contaminated easily due to various kinds of pollutants. Leakage current flows even when surface is dry though magnitude is very low but this leakage current gets strengthened due to increase in humidity, light rain, fog, mist etc. It ultimately leads towards flashover which is highly undesirable. Therefore, condition monitoring of power system insulators is very much necessary. Leakage current monitoring is one of the prime techniques for insulator monitoring. Leakage current consists of both volume current and surface current. Only surface current is affected by external causes like contamination and humidity. Therefore, surface current is a more accurate indicator for condition monitoring. Using harmonic analysis method surface current is extracted from total leakage current. Phase angle analysis at different humidity conditions has been carried out for both total leakage current and surface current. From above mentioned analysis, it may be observed that a significant difference in phase angle may be obtained when only surface current is considered instead of total leakage current. Therefore, this paper gives rise to the possibility of using only surface leakage current for more accurate condition monitoring of insulator.","PeriodicalId":250717,"journal":{"name":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Condition monitoring of 11kV porcelain pin insulator extracting surface current from total leakage current\",\"authors\":\"Suhas Deb, R. Ghosh, S. Dutta, S. Dalai, B. Chatterjee\",\"doi\":\"10.1109/CATCON.2017.8280253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Insulators are one of the most important components of the power system. Outdoor insulators get contaminated easily due to various kinds of pollutants. Leakage current flows even when surface is dry though magnitude is very low but this leakage current gets strengthened due to increase in humidity, light rain, fog, mist etc. It ultimately leads towards flashover which is highly undesirable. Therefore, condition monitoring of power system insulators is very much necessary. Leakage current monitoring is one of the prime techniques for insulator monitoring. Leakage current consists of both volume current and surface current. Only surface current is affected by external causes like contamination and humidity. Therefore, surface current is a more accurate indicator for condition monitoring. Using harmonic analysis method surface current is extracted from total leakage current. Phase angle analysis at different humidity conditions has been carried out for both total leakage current and surface current. From above mentioned analysis, it may be observed that a significant difference in phase angle may be obtained when only surface current is considered instead of total leakage current. Therefore, this paper gives rise to the possibility of using only surface leakage current for more accurate condition monitoring of insulator.\",\"PeriodicalId\":250717,\"journal\":{\"name\":\"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CATCON.2017.8280253\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON.2017.8280253","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

绝缘子是电力系统中最重要的部件之一。室外绝缘子容易受到各种污染物的污染。即使表面干燥,泄漏电流也会流动,虽然强度很低,但由于湿度、小雨、雾、薄雾等的增加,泄漏电流会加强。它最终会导致闪络,这是非常不希望的。因此,对电力系统绝缘子进行状态监测是十分必要的。漏电监测是绝缘子监测的主要技术之一。泄漏电流包括体积电流和表面电流。只有表面电流会受到污染和湿度等外部因素的影响。因此,表面电流是一种较为准确的状态监测指标。利用谐波分析方法从总泄漏电流中提取表面电流。对总泄漏电流和表面电流进行了不同湿度条件下的相位角分析。从上面的分析可以看出,当只考虑表面电流而不考虑总泄漏电流时,相位角会有很大的差异。因此,本文提出了仅使用表面泄漏电流对绝缘子进行更精确状态监测的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Condition monitoring of 11kV porcelain pin insulator extracting surface current from total leakage current
Insulators are one of the most important components of the power system. Outdoor insulators get contaminated easily due to various kinds of pollutants. Leakage current flows even when surface is dry though magnitude is very low but this leakage current gets strengthened due to increase in humidity, light rain, fog, mist etc. It ultimately leads towards flashover which is highly undesirable. Therefore, condition monitoring of power system insulators is very much necessary. Leakage current monitoring is one of the prime techniques for insulator monitoring. Leakage current consists of both volume current and surface current. Only surface current is affected by external causes like contamination and humidity. Therefore, surface current is a more accurate indicator for condition monitoring. Using harmonic analysis method surface current is extracted from total leakage current. Phase angle analysis at different humidity conditions has been carried out for both total leakage current and surface current. From above mentioned analysis, it may be observed that a significant difference in phase angle may be obtained when only surface current is considered instead of total leakage current. Therefore, this paper gives rise to the possibility of using only surface leakage current for more accurate condition monitoring of insulator.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信