{"title":"提高分区供电可靠性","authors":"P. Ilyushin, A. Kulikov","doi":"10.1109/ICIEAM48468.2020.9111937","DOIUrl":null,"url":null,"abstract":"This paper analyzes the general issues of sectionalizing 110- and 220-kV distribution grids, including by current limiting. The results of calculations of transients in the event of various disturbances in the distribution network, taking into account the operation of emergency control devices, are presented. The results of comparative analysis of sectionalized and desectionalized distribution grids are presented. The authors hereof propose introducing a load increment safety factor to quantify how sectionalization or desectionalization could affect grid reliability. The paper further substantiates the need for accounting excess disturbances in sectionalized grids to design and implement measures to minimize accident-related losses. It analyzes the effectiveness of applying automatic load transfer (ALT) and draws recommendations on how to implement it.","PeriodicalId":285590,"journal":{"name":"2020 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving Power Supply Reliability in Case of Sectionalization\",\"authors\":\"P. Ilyushin, A. Kulikov\",\"doi\":\"10.1109/ICIEAM48468.2020.9111937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes the general issues of sectionalizing 110- and 220-kV distribution grids, including by current limiting. The results of calculations of transients in the event of various disturbances in the distribution network, taking into account the operation of emergency control devices, are presented. The results of comparative analysis of sectionalized and desectionalized distribution grids are presented. The authors hereof propose introducing a load increment safety factor to quantify how sectionalization or desectionalization could affect grid reliability. The paper further substantiates the need for accounting excess disturbances in sectionalized grids to design and implement measures to minimize accident-related losses. It analyzes the effectiveness of applying automatic load transfer (ALT) and draws recommendations on how to implement it.\",\"PeriodicalId\":285590,\"journal\":{\"name\":\"2020 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEAM48468.2020.9111937\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM48468.2020.9111937","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文分析了110kv和220kv配电网分段的一般问题,包括限流问题。给出了考虑应急控制装置运行的配电网中各种扰动情况下的暂态计算结果。给出了分段配电网和非分段配电网的对比分析结果。本文作者建议引入负荷增量安全系数来量化分段化或去分段化对电网可靠性的影响。本文进一步证实了在设计和实施措施以尽量减少事故相关损失时,需要对分段电网中的过量干扰进行核算。分析了应用自动负荷转移(ALT)的有效性,并就如何实施它提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improving Power Supply Reliability in Case of Sectionalization
This paper analyzes the general issues of sectionalizing 110- and 220-kV distribution grids, including by current limiting. The results of calculations of transients in the event of various disturbances in the distribution network, taking into account the operation of emergency control devices, are presented. The results of comparative analysis of sectionalized and desectionalized distribution grids are presented. The authors hereof propose introducing a load increment safety factor to quantify how sectionalization or desectionalization could affect grid reliability. The paper further substantiates the need for accounting excess disturbances in sectionalized grids to design and implement measures to minimize accident-related losses. It analyzes the effectiveness of applying automatic load transfer (ALT) and draws recommendations on how to implement it.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信