负载不确定性下无功功率优化

O. Dzobo
{"title":"负载不确定性下无功功率优化","authors":"O. Dzobo","doi":"10.1109/SAUPEC/RobMech/PRASA48453.2020.9040976","DOIUrl":null,"url":null,"abstract":"Reactive power demand in power system networks have a significant effect on energy efficiency in the grid. In locations where there are many industries which have a lot of motors running their production, the inductive power demand from the motors reduce the power factor and increase energy losses during transmission and also limits the real power supplied to the electricity consumer. The monitoring of reactive power in the power system network is difficult because of the challenge of estimating the network load at any given time. In this paper, a case study is presented using the IEEE test network to determine the effect of load uncertainty on reactive power. The uncertainty of the load is achieved by using the two point estimate method. Particle swarm optimization algorithm is used to solve the objective function. The results show that load uncertainty have a significant effect on estimation of reactive power in the system network.","PeriodicalId":215514,"journal":{"name":"2020 International SAUPEC/RobMech/PRASA Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Optimization of reactive power under load uncertainty\",\"authors\":\"O. Dzobo\",\"doi\":\"10.1109/SAUPEC/RobMech/PRASA48453.2020.9040976\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reactive power demand in power system networks have a significant effect on energy efficiency in the grid. In locations where there are many industries which have a lot of motors running their production, the inductive power demand from the motors reduce the power factor and increase energy losses during transmission and also limits the real power supplied to the electricity consumer. The monitoring of reactive power in the power system network is difficult because of the challenge of estimating the network load at any given time. In this paper, a case study is presented using the IEEE test network to determine the effect of load uncertainty on reactive power. The uncertainty of the load is achieved by using the two point estimate method. Particle swarm optimization algorithm is used to solve the objective function. The results show that load uncertainty have a significant effect on estimation of reactive power in the system network.\",\"PeriodicalId\":215514,\"journal\":{\"name\":\"2020 International SAUPEC/RobMech/PRASA Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International SAUPEC/RobMech/PRASA Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SAUPEC/RobMech/PRASA48453.2020.9040976\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International SAUPEC/RobMech/PRASA Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAUPEC/RobMech/PRASA48453.2020.9040976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

电网的无功需求对电网的能效有着重要的影响。在许多有大量电机运行其生产的行业的地方,电机的感应功率需求降低了功率因数,增加了传输过程中的能量损失,也限制了向电力消费者提供的实际功率。电力系统中无功功率的监测是一项艰巨的任务,因为在任何给定的时间都无法估计出电网的负荷。本文以IEEE测试网络为例,分析了负荷不确定性对无功功率的影响。采用两点估计法实现了负荷的不确定性。采用粒子群算法求解目标函数。结果表明,负荷不确定性对电网无功功率估计有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of reactive power under load uncertainty
Reactive power demand in power system networks have a significant effect on energy efficiency in the grid. In locations where there are many industries which have a lot of motors running their production, the inductive power demand from the motors reduce the power factor and increase energy losses during transmission and also limits the real power supplied to the electricity consumer. The monitoring of reactive power in the power system network is difficult because of the challenge of estimating the network load at any given time. In this paper, a case study is presented using the IEEE test network to determine the effect of load uncertainty on reactive power. The uncertainty of the load is achieved by using the two point estimate method. Particle swarm optimization algorithm is used to solve the objective function. The results show that load uncertainty have a significant effect on estimation of reactive power in the system network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信