通过主动防护系统预防和保护火灾危险

Anton Abdullah, Wildan Nugraha, Kusno
{"title":"通过主动防护系统预防和保护火灾危险","authors":"Anton Abdullah, Wildan Nugraha, Kusno","doi":"10.46509/ajtk.v5i2.293","DOIUrl":null,"url":null,"abstract":"This research was conducted to determine the availability and adequacy of the active protection system in the Palembang Aviation Polytechnic area. The Active Protection System is limited to fire alarm systems and detectors. The type of research used is qualitative analysis with an observational approach to analyze fire alarms and detection systems as active protection at the Palembang Aviation Polytechnic. Data collection is carried out by observation and interview. Furthermore, a gap analysis method is carried out to compare the availability of fire alarm and detection systems installed in each building, compared to the expected conditions by applicable regulations, so that gaps can be known from the fire protection system in the building in question. The next step is to decide on the availability and adequacy of the building's fire alarm and detection system and provide recommendations that the manager of the Palembang Aviation Polytechnic may carry out. The results of the application of the fire alarm analysis in the main building are 0% with the inappropriate category, and the average in the study program building is 96.57% with a good category. The implementation of the detection system in the main building is 0% with the inappropriate category (no fire alarm and detection system installed), and the average in the study program building is 97.5% with a good category. Suggestions according to the priority scale are that managers make policies on establishing, maintaining, inspecting, and evaluating active fire protection systems regularly.","PeriodicalId":282183,"journal":{"name":"AIRMAN: Jurnal Teknik dan Keselamatan Transportasi","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fire Hazard Prevention and Protection Through Active Protection System\",\"authors\":\"Anton Abdullah, Wildan Nugraha, Kusno\",\"doi\":\"10.46509/ajtk.v5i2.293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research was conducted to determine the availability and adequacy of the active protection system in the Palembang Aviation Polytechnic area. The Active Protection System is limited to fire alarm systems and detectors. The type of research used is qualitative analysis with an observational approach to analyze fire alarms and detection systems as active protection at the Palembang Aviation Polytechnic. Data collection is carried out by observation and interview. Furthermore, a gap analysis method is carried out to compare the availability of fire alarm and detection systems installed in each building, compared to the expected conditions by applicable regulations, so that gaps can be known from the fire protection system in the building in question. The next step is to decide on the availability and adequacy of the building's fire alarm and detection system and provide recommendations that the manager of the Palembang Aviation Polytechnic may carry out. The results of the application of the fire alarm analysis in the main building are 0% with the inappropriate category, and the average in the study program building is 96.57% with a good category. The implementation of the detection system in the main building is 0% with the inappropriate category (no fire alarm and detection system installed), and the average in the study program building is 97.5% with a good category. Suggestions according to the priority scale are that managers make policies on establishing, maintaining, inspecting, and evaluating active fire protection systems regularly.\",\"PeriodicalId\":282183,\"journal\":{\"name\":\"AIRMAN: Jurnal Teknik dan Keselamatan Transportasi\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIRMAN: Jurnal Teknik dan Keselamatan Transportasi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46509/ajtk.v5i2.293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIRMAN: Jurnal Teknik dan Keselamatan Transportasi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46509/ajtk.v5i2.293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项研究是为了确定巨港航空理工学院地区主动保护系统的可用性和充分性。主动保护系统仅限于火灾报警系统和探测器。使用的研究类型是定性分析,采用观察方法分析巨港航空理工学院的火灾警报和探测系统作为主动保护。数据收集采用观察法和访谈法。此外,采用差距分析方法,将每栋建筑物安装的火灾报警和探测系统的可用性与适用法规的预期条件进行比较,从而可以从有关建筑物的消防系统中了解差距。下一步是决定建筑物的火灾报警和探测系统的可用性和充分性,并提供巨港航空理工学院经理可以执行的建议。火灾报警分析在主楼的应用结果为0%,属于不合格,在研修项目楼的平均应用结果为96.57%,属于良好。探测系统在主楼的执行率为0%,类别不合适(未安装火灾报警和探测系统),在学习计划楼的平均执行率为97.5%,类别良好。根据优先级等级,管理者应定期制定建立、维护、检查和评估现有消防系统的政策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fire Hazard Prevention and Protection Through Active Protection System
This research was conducted to determine the availability and adequacy of the active protection system in the Palembang Aviation Polytechnic area. The Active Protection System is limited to fire alarm systems and detectors. The type of research used is qualitative analysis with an observational approach to analyze fire alarms and detection systems as active protection at the Palembang Aviation Polytechnic. Data collection is carried out by observation and interview. Furthermore, a gap analysis method is carried out to compare the availability of fire alarm and detection systems installed in each building, compared to the expected conditions by applicable regulations, so that gaps can be known from the fire protection system in the building in question. The next step is to decide on the availability and adequacy of the building's fire alarm and detection system and provide recommendations that the manager of the Palembang Aviation Polytechnic may carry out. The results of the application of the fire alarm analysis in the main building are 0% with the inappropriate category, and the average in the study program building is 96.57% with a good category. The implementation of the detection system in the main building is 0% with the inappropriate category (no fire alarm and detection system installed), and the average in the study program building is 97.5% with a good category. Suggestions according to the priority scale are that managers make policies on establishing, maintaining, inspecting, and evaluating active fire protection systems regularly.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信